Nine-year results of Müller cemented titanium Straight Stems in total hip replacement
- PMID: 11510904
- DOI: 10.1007/s004020000254
Nine-year results of Müller cemented titanium Straight Stems in total hip replacement
Abstract
At the Orthopaedic Department of the University of Basel, a total of 540 cemented Müller titanium alloy (Ti6Al7Nb) Straight Stems were inserted between 1989 and 1993. A cohort of 120 consecutive patients (66 women, 54 men) with 126 prostheses operated on between March and December 1989 were followed clinically and radiologically in a prospective manner for a mean observation time of 9.1 years. In all cases, the Müller titanium alloy Straight Stem was combined with the senior author's (E.W.M.) Press-Fit Cup. The mean age of the patients at surgery was 66 (range 43-93) years. Fourty patients (41 hips) died, 9 were interviewed by telephone, none was 'lost to follow-up'. Seventy-one patients with 76 hip replacements were available for the follow-up. Four hips had been revised: two of them due to aseptic loosening of the femoral component, one because of a late infection--all after 9 years--and one owing to a periprosthetic fracture after 6 years. The 9-year overall survivorship is 96.8%, and for aseptic loosening of the stem 98.4%. None of the cups had to be revised for aseptic loosening. The clinical result (according to Merle d'Aubigné) was excellent and good in 88%, moderate in 8%, and poor in 4%. The radiological analysis showed no osteolysis or radiolucent lines in 59 prostheses (78%). Nine stems (12%) showed a radiolucent line. Focal osteolysis was detected in 8 cases (10%) in one or more Gruen zones. The distribution of the osteolyses shows that predominantly zones VII, VI, V, and II are affected in decreasing frequency. No osteolysis was detected on the acetabular side. Our results do not confirm the high rate of osteolysis and revisions with the Müller titanium alloy Straight Stem presented by some other institutions. The verdict on a specific endoprosthetic implant must be made by combined assessment of the design, the implant surface condition, the material, the cement, the cementing procedure and the operative technique. The statement made in earlier publications that cemented titanium alloy should not be used as a femoral stem prosthesis should be reconsidered.
Similar articles
-
Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement. An average ten-year follow-up study.J Bone Joint Surg Am. 1999 Feb;81(2):247-55. doi: 10.2106/00004623-199902000-00012. J Bone Joint Surg Am. 1999. PMID: 10073588
-
Fifteen-year results of the Müller CoCrNiMo straight stem.Arch Orthop Trauma Surg. 2001;121(1-2):38-42. doi: 10.1007/s004020000181. Arch Orthop Trauma Surg. 2001. PMID: 11195116
-
Clinical outcomes of cemented double-tapered titanium femoral stems: a minimum 5-year follow-up.J Orthop Sci. 2011 Nov;16(6):689-97. doi: 10.1007/s00776-011-0154-z. Epub 2011 Sep 16. J Orthop Sci. 2011. PMID: 21922242
-
Cementless cups do not increase osteolysis risk in metal-on-metal total hip arthroplasty. Apropos of 106 cases.Orthop Traumatol Surg Res. 2009 Nov;95(7):478-90. doi: 10.1016/j.otsr.2009.07.007. Epub 2009 Oct 3. Orthop Traumatol Surg Res. 2009. PMID: 19801209
-
Hip prosthetic loosening: A very personal review.World J Orthop. 2021 Sep 18;12(9):629-639. doi: 10.5312/wjo.v12.i9.629. eCollection 2021 Sep 18. World J Orthop. 2021. PMID: 34631447 Free PMC article. Review.
Cited by
-
Is there still a place for the cemented titanium femoral stem? 10,108 cases from the Norwegian Arthroplasty Register.Acta Orthop. 2012 Feb;83(1):1-6. doi: 10.3109/17453674.2011.645194. Epub 2011 Dec 29. Acta Orthop. 2012. PMID: 22206445 Free PMC article.
-
Results of the cementless Plasmacup in revision total hip arthroplasty: a retrospective study of 72 cases with an average follow-up of eight years.BMC Musculoskelet Disord. 2010 May 27;11:101. doi: 10.1186/1471-2474-11-101. BMC Musculoskelet Disord. 2010. PMID: 20507578 Free PMC article.
-
Cement-implant interface contamination: possible reason of inferior clinical outcomes for rough surface cemented stems.Open Orthop J. 2013 Jun 28;7:250-7. doi: 10.2174/1874325001307010250. Print 2013. Open Orthop J. 2013. PMID: 23898352 Free PMC article.
-
Subsidence of titanium straight stems in combination with highly viscous bone cement.Int Orthop. 2005 Apr;29(2):96-100. doi: 10.1007/s00264-004-0631-5. Epub 2005 Feb 10. Int Orthop. 2005. PMID: 15703935 Free PMC article.
-
Total hip replacement with a collarless polished cemented anatomic stem: clinical and gait analysis results at ten years follow-up.Int Orthop. 2014 Apr;38(4):717-24. doi: 10.1007/s00264-013-2186-9. Epub 2013 Dec 19. Int Orthop. 2014. PMID: 24352821 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources