Norwood-type operation with adjustable systemic-pulmonary shunt using hemostatic clip
- PMID: 11515924
- DOI: 10.1016/s0003-4975(01)02664-9
Norwood-type operation with adjustable systemic-pulmonary shunt using hemostatic clip
Abstract
The postoperative course of a patient with hypoplastic left heart syndrome after a first-stage Norwood operation is governed to a large extent by the balance between the systemic and pulmonary circulations. Here we describe a simple and convenient technique for establishing an optimally sized systemic-pulmonary shunt by the application of a hemostatic clip. The method has been used in 6 patients.