Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 Sep 1;51(1):244-54.
doi: 10.1016/s0360-3016(01)01643-1.

Forward or inversely planned segmental multileaf collimator IMRT and sequential tomotherapy to treat multiple dominant intraprostatic lesions of prostate cancer to 90 Gy

Affiliations

Forward or inversely planned segmental multileaf collimator IMRT and sequential tomotherapy to treat multiple dominant intraprostatic lesions of prostate cancer to 90 Gy

P Xia et al. Int J Radiat Oncol Biol Phys. .

Abstract

Purpose: To investigate the technical feasibility of using forward or inversely planned segmental multileaf collimator (SMLC) intensity-modulated radiotherapy and sequential tomotherapy (ST) to escalate to a dose of 90 Gy to multiple dominant intraprostatic lesions within the prostate gland while delivering a dose of 75.6 Gy to the remaining prostate.

Methods and materials: A selected case with one dominant intraprostatic lesion located at the left base and a second dominant intraprostatic lesion at the right apex of the prostate was planned using three different intensity modulation techniques. Two plans were generated with inverse treatment planning, using either SMLC or ST with a special multivane collimator. The third plan also employed SMLC but was generated using forward planning. All three plans were compared based on dose-volume histograms, isodose distributions, and doses to sensitive normal structures.

Results: All three plans meet and exceed the desired dose constraints, limiting doses to the rectum and bladder to an estimated RTOG Grade 2 complication rate of <10%. The ST plan achieved the best dose conformality, whereas the inverse SMLC plan gave the lowest dose to the rectal wall, and the forward SMLC plan obtained the best dose homogeneity inside the targets.

Conclusions: Using any of the three intensity-modulated techniques, it is technically feasible to concurrently treat multiple selected high-risk regions within the prostate to 90 Gy and the remaining prostate to 75.6 Gy, while keeping the doses to the rectum and the bladder significantly lower than those associated with a Grade 2 complication rate of 10%.