Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 Sep 15;121(1-2):134-9.
doi: 10.1016/s0379-0738(01)00463-7.

Spectra interference between diquat and paraquat by second derivative spectrophotometry

Affiliations

Spectra interference between diquat and paraquat by second derivative spectrophotometry

T L Kuo et al. Forensic Sci Int. .

Abstract

A rapid and accurate method, combining solid-phase extraction and second-order derivative spectrophotomety approaches, is developed for the simultaneous determination of diquat (DQ) and paraquat (PQ) in blood, tissue and urine samples. Supernatant resulting from the precipitation of protein (with trichloroacetic acid) in plasma and tissue or Amberlite IRA-401 resin treated urine are passed through a mini-column packed with Wakogel gel (Silica gel). Analytes are then eluted with a non-organic solvent, 0.2mol/l HCl solution containing 2mol/l NH(4)Cl. UV spectrum of the eluent in 220-350nm range provides effective screen to detect the presence of DQ and/or PQ. In the presence of DQ or PQ alone, the analyte present is quantitated by conventional zero- or second-order derivative spectrophotometry. The calibration curve in the 0.1-5.0mg/l range for either analyte obeys Beer's law. When both DQ and PQ are present, their concentrations are determined by the peak amplitudes of their respective second-derivative spectra after the addition of alkaline dithionite reagent. Interference is negligible when the DQ/PQ concentration ratio is within the 5.0-0.2 range. Using a 2-ml of sample size, the detection limits for DQ and PQ in plasma are 0.02 and 0.005mg/l. The corresponding detection limits for urine samples (10ml sample size) are 0.004 and 0.001mg/l. Recoveries of DQ and PQ in triplicate plasma and urine samples spiked with 0.5mg/l of analytes are 93 and 85%. The precision of the proposed method resulting from triplicate study of spiked urine samples varies from 3.2 to 4.6% at 0.5mg/l of DQ and PQ, respectively.

PubMed Disclaimer

Publication types

LinkOut - more resources