Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 Jul;39(4):447-54.
doi: 10.1007/BF02345367.

Noninvasive characterisation of multiple ventricular events using electrocardiographic imaging

Affiliations

Noninvasive characterisation of multiple ventricular events using electrocardiographic imaging

R Hren et al. Med Biol Eng Comput. 2001 Jul.

Abstract

Distributions of epicardial potentials, calculated from body surface electrocardiograms (ECGs), were investigated to determine if they could enable detection of multiple sites of ventricular activity. An anatomical model of the human ventricular myocardium was used to simulate activation sequences initiated at nine different ventricular pairs of sites. From these sequences, body surface ECGs were simulated at 352 sites on the torso surface and then used to reconstruct epicardial potentials at 202 sites. The criterion for detection of dual ventricular events was the presence of two distinct primary potential minima in the reconstructed epicardial potentials. The shortest distance between the two events in the right ventricle that resulted in the reconstruction of epicardial potential patterns, featuring two minima, was 27 mm; the distance between the two events in the left ventricle was 23 mm. When Gaussian white noise in the simulated body surface potentials was increased from 3 microV to 15 microV and 50 microV, dual events became more difficult to distinguish. Findings indicate that calculated epicardial potentials provide useful visual information about the presence of multiple ventricular events that is not apparent in features of body surface ECGs, and could be particularly helpful in optimising mapping procedures during difficult or unsuccessful radiofrequency ablations of accessory pathways.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Phys Med Biol. 1998 Jun;43(6):1449-68 - PubMed
    1. Circulation. 1993 Nov;88(5 Pt 1):2290-306 - PubMed
    1. Circulation. 1990 Sep;82(3):879-96 - PubMed
    1. Circulation. 1994 Jul;90(1):462-8 - PubMed
    1. IEEE Trans Biomed Eng. 1994 Mar;41(3):249-56 - PubMed

Publication types