Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 Aug 28;104(9):976-8.
doi: 10.1161/hc3401.095705.

Annulus paradoxus: transmitral flow velocity to mitral annular velocity ratio is inversely proportional to pulmonary capillary wedge pressure in patients with constrictive pericarditis

Affiliations

Annulus paradoxus: transmitral flow velocity to mitral annular velocity ratio is inversely proportional to pulmonary capillary wedge pressure in patients with constrictive pericarditis

J W Ha et al. Circulation. .

Abstract

Background: The early diastolic velocity of the mitral annulus (E') is reduced in patients with diastolic dysfunction and increased filling pressures. Because transmitral inflow early velocity (E) increases progressively with higher filling pressures, E/E' has been shown to have a strong positive relationship with pulmonary capillary wedge pressure (PCWP) and left ventricular end-diastolic pressure. However, previous studies have primarily involved patients without a pericardial abnormality. In constrictive pericarditis (CP), E' is not reduced, despite increased filling pressures. This study evaluated the relationship between E/E' and PCWP in patients with CP.

Methods and results: We studied 10 patients (8 men; mean age, 64+/-7 years) with surgically confirmed CP. Doppler echocardiography was performed to measure early and late diastolic transmitral flow velocities. Tissue Doppler echocardiography was performed to measure E'. PCWP was measured with right heart catheterization. All patients were in sinus rhythm. Mean E and E' were 91+/-15 cm/s and 11+/-4 cm/s, respectively. Mean PCWP was 25+/-6 mm Hg. E' was positively correlated with PCWP (r=0.69, P=0.027). There was a significant inverse correlation between E/E' and PCWP (r=-0.74, P=0.014). Despite high left ventricular filling pressures, E/E' (mean, 9+/-4) was <15 in all but 1 patient.

Conclusions: Paradoxical to the positive correlation between E/E' and PCWP in patients with myocardial disease, an inverse relationship was found in patients with CP.

PubMed Disclaimer

Publication types

LinkOut - more resources