Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 Aug 28;104(9):1029-33.
doi: 10.1161/hc3401.095097.

Staphylococcus aureus bacteremia in patients with permanent pacemakers or implantable cardioverter-defibrillators

Affiliations

Staphylococcus aureus bacteremia in patients with permanent pacemakers or implantable cardioverter-defibrillators

A L Chamis et al. Circulation. .

Abstract

Background: Although cardiac device infections (CDIs) are a devastating complication of permanent pacemakers or implantable cardioverter-defibrillators, the incidence of CDI in patients with bacteremia is not well defined. The objective of this study was to determine the incidence of CDI among patients with permanent pacemakers or implantable cardioverter-defibrillators who develop Staphylococcus aureus bacteremia (SAB).

Methods and results: A cohort of all adult patients with SAB and permanent pacemakers or implantable cardioverter-defibrillators over a 6-year period was evaluated prospectively. The overall incidence of confirmed CDI was 15 of 33 (45.4%). Confirmed CDI occurred in 9 of the 12 patients (75%) with early SAB (<1 year after device placement). Fifteen of 21 patients (71.5%) with late SAB (>/=1 year after device placement) had either confirmed (6 of 21, 28.5%) or possible (9 of 21, 43%) CDI. In 60% of the patients (9 of 15) with confirmed CDI, no local signs or symptoms suggesting generator pocket infection were noted.

Conclusions: The incidence of CDI among patients with SAB and cardiac devices is high. Neither physical examination nor echocardiography can exclude the possibility of CDI. In patients with early SAB, the device is usually involved, and approximately 40% of these patients have obvious clinical signs of cardiac device involvement. Conversely, in patients with late SAB, the cardiac device is rarely the initial source of bacteremia, and there is a paucity of local signs of device involvement. The cardiac device is involved, however, in >/=28% of these patients.

PubMed Disclaimer

Publication types

MeSH terms

Substances