Risk factors for intrauterine device failure: a review
- PMID: 11535211
- DOI: 10.1016/s0010-7824(01)00215-3
Risk factors for intrauterine device failure: a review
Abstract
After reviewing the literature on intrauterine devices (IUDs) published over the last 30 years, we selected and analyzed recent and most relevant (with appropriate methodology design) articles dealing with the risk factors for IUD failure. There is sufficient evidence to conclude that the TCu380 and levonorgestrel-releasing (LNG) IUD are the most effective, with a cumulative pregnancy rate of less than 2% at 12 years for the TCu380 and around 1% for the LNG IUD at 7 years. In addition, advancing age increases IUD effectiveness, and displacement of the IUD decreases effectiveness. The IUDs with the highest copper concentrations are clearly less prone to failure than those with lower copper concentrations.
Comment in
-
Risk factors for intrauterine device failure: a review.Contraception. 2002 Nov;66(5):385; author reply 385-6. doi: 10.1016/s0010-7824(02)00339-6. Contraception. 2002. PMID: 12443972 No abstract available.
Similar articles
-
Intrauterine devices. The optimal long-term contraceptive method?J Reprod Med. 1999 Mar;44(3):269-74. J Reprod Med. 1999. PMID: 10202746 Review.
-
An evaluation of the levonorgestrel-releasing IUD: its advantages and disadvantages when compared to the copper-releasing IUDs.Contraception. 1991 Dec;44(6):573-88. doi: 10.1016/0010-7824(91)90078-t. Contraception. 1991. PMID: 1773615 Review.
-
Intrauterine devices: an effective alternative to oral hormonal contraception.Prescrire Int. 2009 Jun;18(101):125-30. Prescrire Int. 2009. PMID: 19637436
-
Two years of intrauterine contraception with levonorgestrel and with copper: a randomized comparison of the TCu 380Ag and levonorgestrel 20 mcg/day devices.Contraception. 1987 Mar;35(3):245-55. doi: 10.1016/0010-7824(87)90026-6. Contraception. 1987. PMID: 3111785 Clinical Trial.
-
Extended use of the intrauterine device: a literature review and recommendations for clinical practice.Contraception. 2014 Jun;89(6):495-503. doi: 10.1016/j.contraception.2014.02.011. Epub 2014 Feb 26. Contraception. 2014. PMID: 24679478 Review.
Cited by
-
Comparing the effect of mefenamic Acid and vitex agnus on intrauterine device induced bleeding.J Caring Sci. 2013 Aug 31;2(3):245-54. doi: 10.5681/jcs.2013.030. eCollection 2013 Sep. J Caring Sci. 2013. PMID: 25276733 Free PMC article.
-
[The family doctor facing IUD insertion].Aten Primaria. 2005 Dec;36(10):576-84. doi: 10.1016/s0212-6567(05)70570-9. Aten Primaria. 2005. PMID: 16507294 Free PMC article. Review. Spanish. No abstract available.
-
True Mirena failure: Twin pregnancy with Mirena in situ.J Midlife Health. 2013 Jan;4(1):54-6. doi: 10.4103/0976-7800.109640. J Midlife Health. 2013. PMID: 23833537 Free PMC article.
-
Levonorgestrel intrauterine device with absence of threads: don't take expulsion for granted! A case series of possible errors in ultrasound evaluation, in case of "lost IUDs".J Ultrasound. 2025 Mar;28(1):203-207. doi: 10.1007/s40477-023-00807-2. Epub 2023 Jul 29. J Ultrasound. 2025. PMID: 37516719
-
Contraception choice for HIV positive women.Sex Transm Infect. 2004 Jun;80(3):167-73. doi: 10.1136/sti.2003.008441. Sex Transm Infect. 2004. PMID: 15169996 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources