Effect of windowing and zero-filled reconstruction of MRI data on spatial resolution and acquisition strategy
- PMID: 11536404
- DOI: 10.1002/jmri.1183
Effect of windowing and zero-filled reconstruction of MRI data on spatial resolution and acquisition strategy
Abstract
Standard, MR spin-warp sampling strategies acquire data on a rectangular k-space grid. That method samples data from the "corners" of k-space, i.e., data that lie in a region of k-space outside of an ellipse just inscribed in the rectangular boundary. Illustrative calculations demonstrate that the data in the corners of k-space contribute to the useful resolution only if an interpolation method such as a zero-filled reconstruction is used. The consequences of this finding on data acquisition and data windowing strategies are discussed. A further implication of this result is that the spatial resolution of images reconstructed with zero-filling (but without radial windowing) is expected to display angular dependence, even when the phase- and frequency-encoded resolutions are identical. This hypothesis is experimentally verified with a slit geometry phantom. It is also observed that images reconstructed without zero-filling do not display the angular dependence of spatial resolution predicted solely by the maximal k-space extent of the raw data. The implications of these results for 3D contrast-enhanced angiographic acquisitions with elliptical centric view ordering are explored with simulations.
Copyright 2001 Wiley-Liss, Inc.
Similar articles
-
Undersampled elliptical centric view-order for improved spatial resolution in contrast-enhanced MR angiography.Magn Reson Med. 2006 Jan;55(1):50-8. doi: 10.1002/mrm.20726. Magn Reson Med. 2006. PMID: 16315207
-
Fast single image super-resolution using estimated low-frequency k-space data in MRI.Magn Reson Imaging. 2017 Jul;40:1-11. doi: 10.1016/j.mri.2017.03.008. Epub 2017 Mar 31. Magn Reson Imaging. 2017. PMID: 28366758
-
Spatial and temporal resolution effects on dynamic contrast-enhanced magnetic resonance mammography.Magn Reson Imaging. 2007 Jan;25(1):14-34. doi: 10.1016/j.mri.2006.09.025. Epub 2006 Nov 30. Magn Reson Imaging. 2007. PMID: 17222712
-
Prior data assisted compressed sensing: a novel MR imaging strategy for real time tracking of lung tumors.Med Phys. 2014 Aug;41(8):082301. doi: 10.1118/1.4885960. Med Phys. 2014. PMID: 25086550
-
Experimental evaluation and basis function optimization of the spatially variant image-space PSF on the Ingenuity PET/MR scanner.Med Phys. 2014 Jun;41(6):062501. doi: 10.1118/1.4875689. Med Phys. 2014. PMID: 24877835
Cited by
-
Super-resolution reconstruction in ultrahigh-field MRI.Biophys Rep (N Y). 2023 Mar 29;3(2):100107. doi: 10.1016/j.bpr.2023.100107. eCollection 2023 Jun 14. Biophys Rep (N Y). 2023. PMID: 37114210 Free PMC article.
-
Five-minute knee MRI for simultaneous morphometry and T2 relaxometry of cartilage and meniscus and for semiquantitative radiological assessment using double-echo in steady-state at 3T.J Magn Reson Imaging. 2018 May;47(5):1328-1341. doi: 10.1002/jmri.25883. Epub 2017 Nov 1. J Magn Reson Imaging. 2018. PMID: 29090500 Free PMC article.
-
Max CAPR: high-resolution 3D contrast-enhanced MR angiography with acquisition times under 5 seconds.Magn Reson Med. 2010 Oct;64(4):1171-81. doi: 10.1002/mrm.22434. Magn Reson Med. 2010. PMID: 20715291 Free PMC article.
-
Regional cortical perfusion increases induced by a 6-month endurance training in young sedentary adults.Front Aging Neurosci. 2022 Aug 9;14:951022. doi: 10.3389/fnagi.2022.951022. eCollection 2022. Front Aging Neurosci. 2022. PMID: 36034125 Free PMC article.
-
Complete intracranial arterial and venous blood flow evaluation with 4D flow MR imaging.AJNR Am J Neuroradiol. 2009 Feb;30(2):362-6. doi: 10.3174/ajnr.A1138. Epub 2008 Jul 24. AJNR Am J Neuroradiol. 2009. PMID: 18653687 Free PMC article. Clinical Trial.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical