Results of dosimetric measurements in space missions
- PMID: 11540535
- DOI: 10.1093/oxfordjournals.rpd.a031988
Results of dosimetric measurements in space missions
Abstract
Detector packages consisting of thermoluminescence detectors (TLDs), nuclear emulsions and plastic nuclear track detectors were exposed in different locations inside spacecraft. The detector systems, which supplement each other in their registration characteristics, allow the recording of biologically relevant portions of the radiation field independently. Results are presented and compared with calculations. Dose equivalents for the astronauts have been calculated based on the measurements; they lie between 190 microSv d-1 and 860 microSv d-1.
Similar articles
-
Space radiation dosimetry.Acta Astronaut. 1994 Nov;32(11):715-20. doi: 10.1016/0094-5765(94)90165-1. Acta Astronaut. 1994. PMID: 11538447
-
Results of dosimetric measurements in space missions.Adv Space Res. 1998;22(4):495-500. doi: 10.1016/s0273-1177(98)01069-2. Adv Space Res. 1998. PMID: 11542777
-
Dosimetric mapping in BIORACK on IML2.J Biotechnol. 1996 Jun 27;47(2-3):83-8. doi: 10.1016/0168-1656(96)01372-7. J Biotechnol. 1996. PMID: 11536771
-
Space radiation dosimetry in low-Earth orbit and beyond.Nucl Instrum Methods Phys Res B. 2001 Sep;184(1-2):255-94. doi: 10.1016/s0168-583x(01)00748-0. Nucl Instrum Methods Phys Res B. 2001. PMID: 11863032 Review.
-
Neutron measurements onboard the space shuttle.Radiat Meas. 2001 Jun;33(3):235-41. doi: 10.1016/s1350-4487(00)00159-1. Radiat Meas. 2001. PMID: 11852943 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources