Utility of cardiac troponin measurement after cardiac surgery
- PMID: 11557251
- DOI: 10.1016/s0009-8981(01)00556-3
Utility of cardiac troponin measurement after cardiac surgery
Abstract
Postoperative cardiac failure due to myocardial necrosis remains a major complication in cardiac surgical procedures and its diagnosis is still difficult. In fact, cardiac enzymes, electrocardiogram and echographic signs are often misleading. The prognostic valve of troponin I after coronary artery bypass or conventional value surgery has been evaluated in 500 adult patients. Postoperative troponin I concentrations after cardiac surgery represent an independent variable associated with mortality (in-hospital death) and morbidity (low cardiac output and acute renal failure).
Publication types
MeSH terms
Substances