Improved methods for construction of carbon fibre electrodes for extracellular spike recording
- PMID: 11564518
- DOI: 10.1016/s0165-0270(01)00411-3
Improved methods for construction of carbon fibre electrodes for extracellular spike recording
Abstract
Microelectrodes using single carbon fibres as the conducting element have been used since 1979 for electrophysiological measurements in vivo and in vitro. However, there is still considerable discussion about the manufacture of these electrodes, and no overall agreement as to the best way to minimise electrode noise. In this article we describe some revised methods for carbon fibre electrode manufacture, which we believe, gives the lowest noise performance for spike recording in vivo.
Similar articles
-
Toward a comparison of microelectrodes for acute and chronic recordings.Brain Res. 2009 Jul 28;1282:183-200. doi: 10.1016/j.brainres.2009.05.052. Epub 2009 May 30. Brain Res. 2009. PMID: 19486899
-
A CMOS-based microelectrode array for interaction with neuronal cultures.J Neurosci Methods. 2007 Aug 15;164(1):93-106. doi: 10.1016/j.jneumeth.2007.04.006. Epub 2007 Apr 19. J Neurosci Methods. 2007. PMID: 17540452
-
Extracellular recordings from locally dense microelectrode arrays coupled to dissociated cortical cultures.J Neurosci Methods. 2009 Mar 15;177(2):386-96. doi: 10.1016/j.jneumeth.2008.10.032. Epub 2008 Nov 5. J Neurosci Methods. 2009. PMID: 19027792
-
Nanostructuration strategies to enhance microelectrode array (MEA) performance for neuronal recording and stimulation.J Physiol Paris. 2012 May-Aug;106(3-4):137-45. doi: 10.1016/j.jphysparis.2011.10.001. Epub 2011 Oct 18. J Physiol Paris. 2012. PMID: 22027264 Review.
-
In vivo electrophysiological detection of myocardial ischemia through monophasic action potential recording.Prog Cardiovasc Dis. 1991 Jul-Aug;34(1):15-28. doi: 10.1016/0033-0620(91)90016-f. Prog Cardiovasc Dis. 1991. PMID: 2063010 Review. No abstract available.
Cited by
-
Are striatal tyrosine hydroxylase interneurons dopaminergic?J Neurosci. 2015 Apr 22;35(16):6584-99. doi: 10.1523/JNEUROSCI.0195-15.2015. J Neurosci. 2015. PMID: 25904808 Free PMC article.
-
Method for the construction and use of carbon fiber multibarrel electrodes for deep brain recordings in the alert animal.J Neurosci Methods. 2009 Apr 15;178(2):255-62. doi: 10.1016/j.jneumeth.2008.12.009. Epub 2008 Dec 14. J Neurosci Methods. 2009. PMID: 19135083 Free PMC article.
-
Laser Sharpening of Carbon Fiber Microelectrode Arrays for Brain Recording.J Micro Nanomanuf. 2020 Dec 1;8(4):041013. doi: 10.1115/1.4049780. Epub 2021 Feb 12. J Micro Nanomanuf. 2020. PMID: 35833189 Free PMC article.
-
Inhibition of striatal dopamine release by CB1 receptor activation requires nonsynaptic communication involving GABA, H2O2, and KATP channels.Neurochem Int. 2008 Jan;52(1-2):80-8. doi: 10.1016/j.neuint.2007.07.014. Epub 2007 Jul 22. Neurochem Int. 2008. PMID: 17767979 Free PMC article.
-
Mobilization of calcium from intracellular stores facilitates somatodendritic dopamine release.J Neurosci. 2009 May 20;29(20):6568-79. doi: 10.1523/JNEUROSCI.0181-09.2009. J Neurosci. 2009. PMID: 19458227 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources