Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 Oct;16(10):2079-81.
doi: 10.1093/ndt/16.10.2079.

Tenckhoff catheters post-renal transplantation: the 'pull' technique?

Affiliations

Tenckhoff catheters post-renal transplantation: the 'pull' technique?

I M Quiroga et al. Nephrol Dial Transplant. 2001 Oct.

Abstract

Background: Tenckhoff catheters are used widely for the provision of continuous ambulatory peritoneal dialysis. Traditionally these catheters are removed surgically under anaesthesia. We set out to introduce and monitor prospectively a technique for removal of the Tenckhoff catheter by a 'pull' technique. The intention was to avoid the discomfort, risk and cost of traditional surgery.

Methods: Over a 1-year period all renal transplant patients having their Tenckhoff catheter removed by this technique were monitored prospectively. All patients were followed for a minimum 2-year period after removal. In the pull technique steady non-jerky traction is applied to the catheter. Complications such as catheter breakage and cuff related sepsis were recorded.

Results: Sepsis related to a retained cuff occurred in only one patient early in the series. There were no other complications. The procedure was well tolerated. Use of local anaesthesia used initially, was largely phased out over the course of study and the procedure moved from the theatre to the ward.

Conclusions: The pull technique is safe and well tolerated. The technique has significant advantages in selected patients without a history of recent peritonitis or exit site infection, in reducing risk to the patients, the pain of abdominal wall surgery and reduced usage of costly theatre time and in-patient beds.

PubMed Disclaimer

Comment in

  • Tenckhoff catheters: the pull technique.
    Quiroga I, Reddy SP, Bhattacharjya S, Darby CR. Quiroga I, et al. Nephrol Dial Transplant. 2003 Aug;18(8):1682. doi: 10.1093/ndt/gfg173. Nephrol Dial Transplant. 2003. PMID: 12897121 No abstract available.