Contrast-enhanced near-infrared laser mammography with a prototype breast scanner: feasibility study with tissue phantoms and preliminary results of imaging experimental tumors
- PMID: 11577267
- DOI: 10.1097/00004424-200110000-00002
Contrast-enhanced near-infrared laser mammography with a prototype breast scanner: feasibility study with tissue phantoms and preliminary results of imaging experimental tumors
Abstract
Rationale and objectives: Near-infrared (NIR) optical mammography without contrast has a low specificity. The application of optical contrast medium may improve the performance. The concentration-dependent detectability of a new NIR contrast medium was determined with a prototype optical breast scanner. In vivo imaging of experimental tumors was performed.
Methods: The NIR contrast agent NIR96010 is a newly synthesized, hydrophilic contrast agent for NIR mammography. A concentration-dependent contrast resolution was determined for tissue phantoms consisting of whole milk powder and gelatin. A central part of the phantoms measuring 2 x 2 cm2 without contrast was replaced with phantom material containing 1 micromol/L to 25 nmol/L NIR96010. The composite phantoms were measured with a prototype NIR breast scanner with lasers of lambda1 = 785 nm and lambda2 = 850 nm wavelength. Intensity profiles and standard deviations of the transmission signal in areas with and without contrast were determined by linear fit procedures. Signal-to-noise ratios and spatial resolution as a function of contrast concentration were determined. Near-infrared imaging of five tumor-bearing SCID mice (MX1 breast adenocarcinoma, tumor diameter 5-10 mm) was performed before and after intravenous application of 2 micromol/kg NIR96010.
Results: Spectrometry showed an absorption maximum of the contrast agent at 755 nm. No spectral shifts occurred in protein-containing solution. Signal-to-noise ratio in the transmission intensity profiles ranged from 1.1 at 25 nmol/L contrast to 28 at 1 micromol/L. At concentrations <40 nmol/L, no differentiation from the background was possible. The transitional area between the contrast-free edge of the phantom and the central contrast-containing part appeared in the profiles as a steep increase with a width of 4.2 +/- 1.8 mm. The experimental tumors were detectable in nonenhanced images as well as contrast-enhanced images, with better delineation after contrast administration. In postcontrast absorption profiles, a 44.1% +/- 11.3% greater absorption increase was seen in tumor tissue compared with normal tissue.
Conclusions: The laser wavelength lambda1 of the prototype laser mammography device was not situated at maximum absorption of the contrast agent NIR96010 but on the descending shoulder of the absorption spectrum. This implies a 20% signal loss for contrast detection. Despite the nonideal measurement conditions, concentrations as low as 40 nmol/L were detectable in vitro. In vivo, all tumors were detectable in color-coded nonenhanced scans as well as in contrast-enhanced scans, with better delineation after contrast administration.
Similar articles
-
Near-infrared imaging of the breast using omocianine as a fluorescent dye: results of a placebo-controlled, clinical, multicenter trial.Invest Radiol. 2011 Nov;46(11):697-704. doi: 10.1097/RLI.0b013e318229ff25. Invest Radiol. 2011. PMID: 21788905 Clinical Trial.
-
Near-infrared fluorescent dyes for enhanced contrast in optical mammography: phantom experiments.J Biomed Opt. 2001 Apr;6(2):134-40. doi: 10.1117/1.1350561. J Biomed Opt. 2001. PMID: 11375722
-
[The clinical detection of breast cancer by spectrum method].Guang Pu Xue Yu Guang Pu Fen Xi. 2008 Nov;28(11):2531-5. Guang Pu Xue Yu Guang Pu Fen Xi. 2008. PMID: 19271483 Chinese.
-
Photoacoustic breast tomography prototypes with reported human applications.Eur Radiol. 2015 Aug;25(8):2205-13. doi: 10.1007/s00330-015-3647-x. Epub 2015 Feb 27. Eur Radiol. 2015. PMID: 25721319 Review.
-
[Contrast media for optical mammography].Radiologe. 1997 Sep;37(9):749-55. doi: 10.1007/s001170050277. Radiologe. 1997. PMID: 9424621 Review. German.
Cited by
-
Tissue-like phantoms for near-infrared fluorescence imaging system assessment and the training of surgeons.J Biomed Opt. 2006 Jan-Feb;11(1):014007. doi: 10.1117/1.2170579. J Biomed Opt. 2006. PMID: 16526884 Free PMC article.
-
A review of performance of near-infrared fluorescence imaging devices used in clinical studies.Br J Radiol. 2015 Jan;88(1045):20140547. doi: 10.1259/bjr.20140547. Br J Radiol. 2015. PMID: 25410320 Free PMC article. Review.
-
Differentiation of angiogenic burden in human cancer xenografts using a perfusion-type optical contrast agent (SIDAG).Breast Cancer Res. 2008;10(2):R23. doi: 10.1186/bcr1875. Epub 2008 Mar 10. Breast Cancer Res. 2008. PMID: 18331624 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical