Magnetic resonance imaging of the lung with a volumetric interpolated 3D-gradient echo sequence
- PMID: 11588673
- DOI: 10.1055/s-2001-17585
Magnetic resonance imaging of the lung with a volumetric interpolated 3D-gradient echo sequence
Abstract
Objective: To evaluate the feasibility of a magnetic resonance imaging protocol for the lung using a volumetric interpolated 3D-gradient echo sequence (3D-GRE).
Subjects and methods: A T(1)-weighted 3D-GRE sequence was used for volumetric interpolated breath-hold examinations ("VIBE") of the lung in twelve healthy volunteers (TR/TE 4.5/1.9 ms, flip-angle 12 degrees, matrix 502 X 512 [interpolated]). Three coronal 80 mm slabs (16 aportitions, 2.5 mm slices) were added to 3D data sets for multi-planar reformations. No contrast material was applied. Artifacts and resolution o vessel and airway structures in each lung segment were evaluated by two observers (12 volunteers, 228 lung segments).
Results: The protocol provided excellent images of vascular and tracheo-bronchial structures with very moderate pulsation artifacts. 224/228 lung segments were imaged with "good" (146/228) or "sufficient" quality (78/228). Segmental and sub-segmental vessels (5th order) were identified due to bright flow signal without administration of contrast material. Walls of segmental bronchi (3rd order) were delineated in all parts of the lung.
Conclusions: The high spatial resolution, the excellent visualization of lung anatomy, the low rate of artifacts without respiratory triggering and the short acquisition times are clear advantages of the 3D-GRE (VI-BE) sequence compared to existing 2D-GRE strategies for MRI of the lung.
Similar articles
-
Noncontrast-enhanced three-dimensional magnetic resonance aortography of the thorax at 3.0 T using respiratory-compensated T1-weighted k-space segmented gradient-echo imaging with radial data sampling: preliminary study.Invest Radiol. 2009 Sep;44(9):548-52. doi: 10.1097/RLI.0b013e3181b4c0ec. Invest Radiol. 2009. PMID: 19652612
-
Free-breathing 3D T1-weighted gradient-echo sequence with radial data sampling in abdominal MRI: preliminary observations.AJR Am J Roentgenol. 2011 Sep;197(3):650-7. doi: 10.2214/AJR.10.5881. AJR Am J Roentgenol. 2011. PMID: 21862807
-
Abdominal MR imaging with a volumetric interpolated breath-hold examination.Radiology. 1999 Sep;212(3):876-84. doi: 10.1148/radiology.212.3.r99se34876. Radiology. 1999. PMID: 10478260
-
[Magnetic resonance imaging in the evaluation of pneumonia].Radiologe. 2006 Apr;46(4):267-70, 272-4. doi: 10.1007/s00117-005-1326-7. Radiologe. 2006. PMID: 16395604 Review. German.
-
Improvement of 3D acquisition and visualization in MRI.Magn Reson Imaging. 1991;9(4):597-609. doi: 10.1016/0730-725x(91)90048-q. Magn Reson Imaging. 1991. PMID: 1779732 Review.
Cited by
-
[MRI in staging of lung cancer].Radiologe. 2006 Apr;46(4):251-4, 256-9. doi: 10.1007/s00117-005-1334-7. Radiologe. 2006. PMID: 16440188 Review. German.
-
[New procedures. Comprehensive staging of lung cancer by MRI].Radiologe. 2010 Aug;50(8):699-705. doi: 10.1007/s00117-009-1959-z. Radiologe. 2010. PMID: 20628723 Review. German.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical