Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2001 Nov;54(5):600-4.
doi: 10.1067/mge.2001.118945.

Diagnostic quality of biopsy specimens: comparison between a conventional biopsy forceps and multibite forceps

Affiliations
Clinical Trial

Diagnostic quality of biopsy specimens: comparison between a conventional biopsy forceps and multibite forceps

A C Fantin et al. Gastrointest Endosc. 2001 Nov.

Abstract

Background: The endoscopic biopsy is a prerequisite for histopathologic diagnosis. Various types of forceps are used to obtain tissue specimens. The aim of this study was to assess and compare the diagnostic quality of biopsy specimens obtained with a conventional forceps and a Multibite forceps.

Methods: In a prospective, partially blinded, and randomized trial that included 250 patients referred for diagnostic upper and/or lower endoscopy, 510 biopsy specimens obtained with the Multibite forceps were compared with 520 specimens obtained with a conventional forceps. An experienced, blinded pathologist evaluated the specimens for diameter, depth of specimen, artifacts, anatomic orientation, vitality, general histologic quality, and diagnostic quality. Statistical analysis was performed by using the Fisher exact test. A p value of < 0.05 was regarded as significant.

Results: There were no statistically significant differences between the specimens obtained with the 2 forceps. The p values for the evaluated parameters were as follows: diameter 0.45, depth of specimen 0.56, artifacts 1.0, pathoanatomic orientation 0.40, vitality 0.45, and histologic diagnostic quality 0.53.

Conclusion: The quality of biopsy specimens obtained with the Multibite forceps is comparable with that of specimens taken with a conventional forceps. Use of the Multibite forceps saves time in that 4 specimens can be obtained in 1 pass in situations in which a large number of specimens are needed or when the potential for transmission of infection is of concern.

PubMed Disclaimer

LinkOut - more resources