Clinical evaluation of the GlucoWatch biographer: a continual, non-invasive glucose monitor for patients with diabetes
- PMID: 11679237
- DOI: 10.1016/s0956-5663(01)00189-0
Clinical evaluation of the GlucoWatch biographer: a continual, non-invasive glucose monitor for patients with diabetes
Abstract
A device providing frequent, automatic, and non-invasive glucose measurements for persons with diabetes has been developed: the GlucoWatch biographer. This device extracts glucose through intact skin via reverse iontophoresis where it is detected by an amperometric biosensor. The biographer can provide glucose readings every 20 min for 12 h. The performance of this device was evaluated in two large clinical studies in a controlled clinical environment (n=231), and the home environment (n=124). Accuracy of the biographer was evaluated by comparing the automatic biographer readings to serial finger-stick blood glucose (BG) measurements. Biographer performance was comparable in both environments. Mean difference between biographer and finger-stick measurements was -0.01 and 0.26 mmol l(-1) for the clinical and home environments, respectively. The mean absolute value of the relative difference was 1.06 and 1.18 mmol l(-1) for the same studies. Correlation coefficient (r) between biographer and finger-stick measurements was 0.85 and 0.80 for the two studies. In both studies, over 94% of the biographer readings were in the clinically acceptable A+B region of the Clarke Error Grid. A slight positive bias is observed for the biographer readings at low BG levels. Biographer accuracy is relatively constant over all rates of BG changes, except when BG decreases more than 10 mmol l(-1) h(-1), which occurred for only 0.2% of points in the home environment study. Biographer precision, as measured by CV%, is approx. 10%. Skin irritation, characterized by erythema and edema, was either non-existent or mild in >90% of subjects and resolved in virtually all subjects without treatment in several days.
Similar articles
-
The GlucoWatch biographer: a frequent automatic and noninvasive glucose monitor.Ann Med. 2000 Dec;32(9):632-41. doi: 10.3109/07853890009002034. Ann Med. 2000. PMID: 11209971 Review.
-
Glucose monitoring by reverse iontophoresis.Diabetes Metab Res Rev. 2002 Jan-Feb;18 Suppl 1:S49-53. doi: 10.1002/dmrr.210. Diabetes Metab Res Rev. 2002. PMID: 11921430 Review.
-
Effect of acetaminophen on the accuracy of glucose measurements obtained with the GlucoWatch biographer.Diabetes Technol Ther. 2000 Summer;2(2):199-207. doi: 10.1089/15209150050025140. Diabetes Technol Ther. 2000. PMID: 11469259
-
Noninvasive glucose monitoring: comprehensive clinical results. Cygnus Research Team.JAMA. 1999 Nov 17;282(19):1839-44. doi: 10.1001/jama.282.19.1839. JAMA. 1999. PMID: 10573275
-
Correlation of fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with type 1 diabetes.Diabetes Care. 1999 Oct;22(10):1708-14. doi: 10.2337/diacare.22.10.1708. Diabetes Care. 1999. PMID: 10526740 Clinical Trial.
Cited by
-
Carbon nanotube composites for glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring.Int J Nanomedicine. 2010 May 13;5:343-9. Int J Nanomedicine. 2010. PMID: 20517479 Free PMC article.
-
Highly integrated watch for noninvasive continual glucose monitoring.Microsyst Nanoeng. 2022 Feb 23;8:25. doi: 10.1038/s41378-022-00355-5. eCollection 2022. Microsyst Nanoeng. 2022. PMID: 35310514 Free PMC article.
-
Simultaneous, noninvasive, and transdermal extraction of urea and homocysteine by reverse iontophoresis.Int J Nanomedicine. 2011;6:417-23. doi: 10.2147/IJN.S16418. Epub 2011 Feb 20. Int J Nanomedicine. 2011. PMID: 21499431 Free PMC article.
-
Investigation on cardiovascular risk prediction using physiological parameters.Comput Math Methods Med. 2013;2013:272691. doi: 10.1155/2013/272691. Epub 2013 Dec 31. Comput Math Methods Med. 2013. PMID: 24489599 Free PMC article. Review.
-
Simultaneous transdermal extraction of glucose and lactate from human subjects by reverse iontophoresis.Int J Nanomedicine. 2008;3(2):211-23. doi: 10.2147/ijn.s1728. Int J Nanomedicine. 2008. PMID: 18686780 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical