Calcium measurements in serum and plasma--total and ionized
- PMID: 116800
- DOI: 10.3109/10408367909105859
Calcium measurements in serum and plasma--total and ionized
Abstract
This article will review the methods currently employed for measuring the concentrations of total and ionized calcium in serum or plasma. As far as total calcium is concerned, various techniques such as atomic absorption spectrometry, spectrophotometry, fluorometry, complexometric titration, and flame photometry will be described and compared. Particular emphasis will be given to the accuracy and precision of each technique. Possible sources of error and interfering agents will be identified and the various procedures for the taking and handling of blood samples evaluated. Inter-laboratory variation in the measurement of calcium will be studied. An assessment will be made of a new reference method for measuring total calcium in serum using isotope-dilution mass spectrometry. The usefulness of the total calcium measurement in clinical medicine will be briefly discussed. Within the last decade the refinement of spectrophotometric techniques and the improvements in ion-selective electrode technology have revolutionized the measurement of ionized calcium in serum, such that it may now be possible to replace total calcium measurements with ionized calcium measurements on a routine basis. The various techniques currently in use for measuring ionized calcium will be described and evaluated. Particular attention will be paid to the preparation of standards, the procedures for taking blood samples, and the handling of the samples prior to and during measurement. An assessment of the relative value of measuring total and ionized calcium will be presented.
Similar articles
-
Ionized calcium in body fluids.Crit Rev Clin Lab Sci. 1981;15(2):85-125. doi: 10.3109/10408368109105869. Crit Rev Clin Lab Sci. 1981. PMID: 7026165 Review.
-
[Determination of electrolytes in serum and plasma].Wien Klin Wochenschr Suppl. 1992;192:37-41. Wien Klin Wochenschr Suppl. 1992. PMID: 1502823 Review. German.
-
IFCC recommended reference method for the determination of the substance concentration of ionized calcium in undiluted serum, plasma or whole blood.Clin Chem Lab Med. 2000 Dec;38(12):1301-14. doi: 10.1515/CCLM.2000.206. Clin Chem Lab Med. 2000. PMID: 11205698
-
Validation of candidate reference methods based on ion chromatography for determination of total sodium, potassium, calcium and magnesium in serum through comparison with flame atomic emission and absorption spectrometry.Clin Biochem. 1996 Dec;29(6):501-8. doi: 10.1016/s0009-9120(96)00090-2. Clin Biochem. 1996. PMID: 8939396
-
Ionized calcium in normal serum, ultrafiltrates, and whole blood determined by ion-exchange electrodes.J Clin Invest. 1970 Feb;49(2):318-34. doi: 10.1172/JCI106241. J Clin Invest. 1970. PMID: 4983663 Free PMC article.
Cited by
-
Serum calcium measurement: Total versus free (ionized) calcium.Indian J Clin Biochem. 2005 Jul;20(2):158-61. doi: 10.1007/BF02867418. Indian J Clin Biochem. 2005. PMID: 23105551 Free PMC article.
-
Evaluation of calcium ion release from apical plugs formed by Biodentine and MTA with and without incorporation of triple antibiotic powder and modified triple antibiotic powder (cefaclor) using atomic absorption spectrophotometry - An in vitro study.J Conserv Dent Endod. 2023 Sep-Oct;26(5):519-524. doi: 10.4103/jcd.jcd_250_23. Epub 2023 Sep 16. J Conserv Dent Endod. 2023. PMID: 38292368 Free PMC article.
-
Extracellular calcium alters calcium-sensing receptor network integrating intracellular calcium-signaling and related key pathway.Sci Rep. 2021 Oct 18;11(1):20576. doi: 10.1038/s41598-021-00067-2. Sci Rep. 2021. PMID: 34663830 Free PMC article.
-
Effect of Water Salinity, Dietary Potassium Carbonate, Vitamin D3 Levels, and Vitamin D3 Form (1α-Hydroxycholecalciferol) on Calcium and Phosphorus Digestibility and Tibia Bone Properties in Broilers.J Poult Sci. 2025 Jul 19;62:2025020. doi: 10.2141/jpsa.2025020. eCollection 2025. J Poult Sci. 2025. PMID: 40689229 Free PMC article.
-
New method for calcium on the ADVIA analyzer is free from interference of gadolinium-type contrast agents.J Clin Lab Anal. 2009;23(6):399-403. doi: 10.1002/jcla.20353. J Clin Lab Anal. 2009. PMID: 19927350 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Research Materials