Virtual reality computer animation of the effect of component position and design on stability after total hip arthroplasty
Abstract
Virtual reality technology was utilized to assess the effect of component orientation and component design on the range of motion prior to impingement following total hip arthroplasty. Components were digitized, oriented in the pelvis, and computer animations were performed to assess the likelihood of dislocation with different combinations of component orientation.
Similar articles
-
Stem design and dislocation after revision total hip arthroplasty: clinical results and computer modeling.J Arthroplasty. 2001 Dec;16(8 Suppl 1):8-12. doi: 10.1054/arth.2001.28359. J Arthroplasty. 2001. PMID: 11742444
-
Dislocation after total hip arthroplasty: implant design and orientation.J Am Acad Orthop Surg. 2003 Mar-Apr;11(2):89-99. doi: 10.5435/00124635-200303000-00003. J Am Acad Orthop Surg. 2003. PMID: 12670135 Review.
-
The impingement-dislocation risk of total hip replacement: effects of cup orientation and patient maneuvers.Annu Int Conf IEEE Eng Med Biol Soc. 2012;2012:6801-4. doi: 10.1109/EMBC.2012.6347556. Annu Int Conf IEEE Eng Med Biol Soc. 2012. PMID: 23367491
-
[Method for the evaluation of factors influencing the dislocation stability of total hip endoprotheses].Biomed Tech (Berl). 2004 May;49(5):137-44. doi: 10.1515/BMT.2004.027. Biomed Tech (Berl). 2004. PMID: 15212199 German.
-
Dual mobility in total hip arthroplasty.Orthop Clin North Am. 2014 Jan;45(1):1-8. doi: 10.1016/j.ocl.2013.08.004. Epub 2013 Oct 1. Orthop Clin North Am. 2014. PMID: 24267202 Review.
Cited by
-
Can a simple iPad app improve C-arm based component position in anterior THA?Arch Orthop Trauma Surg. 2021 Aug;141(8):1401-1409. doi: 10.1007/s00402-021-03807-1. Epub 2021 Feb 13. Arch Orthop Trauma Surg. 2021. PMID: 33582865
-
Reliability and validity of measuring acetabular component orientation by plain anteroposterior radiographs.Clin Orthop Relat Res. 2013 Sep;471(9):2987-94. doi: 10.1007/s11999-013-3021-8. Epub 2013 May 4. Clin Orthop Relat Res. 2013. PMID: 23645336 Free PMC article.
-
CORR Insights®: Are Lipped Polyethylene Liners Associated with Increased Revision Rates in Patients with Uncemented Acetabular Components? An Observational Cohort Study.Clin Orthop Relat Res. 2020 Mar;478(3):590-592. doi: 10.1097/CORR.0000000000001127. Clin Orthop Relat Res. 2020. PMID: 31977437 Free PMC article. No abstract available.
-
The Safe Zone Range for Cup Anteversion Is Narrower Than for Inclination in THA.Clin Orthop Relat Res. 2018 Feb;476(2):325-335. doi: 10.1007/s11999.0000000000000051. Clin Orthop Relat Res. 2018. PMID: 29529664 Free PMC article.
-
The Patient-Specific Combined Target Zone for Morpho-Functional Planning of Total Hip Arthroplasty.J Pers Med. 2021 Aug 21;11(8):817. doi: 10.3390/jpm11080817. J Pers Med. 2021. PMID: 34442461 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical