Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2001 Mar 1;37(3):741-7.
doi: 10.1016/s0735-1097(00)01179-7.

Real-time assessment of myocardial perfusion and wall motion during bicycle and treadmill exercise echocardiography: comparison with single photon emission computed tomography

Affiliations
Free article
Comparative Study

Real-time assessment of myocardial perfusion and wall motion during bicycle and treadmill exercise echocardiography: comparison with single photon emission computed tomography

S Shimoni et al. J Am Coll Cardiol. .
Free article

Abstract

Objectives: We sought to determine the feasibility and accuracy of real-time imaging of myocardial contrast echocardiography (MCE) in detecting myocardial perfusion defects during exercise echocardiography compared with radionuclide tomography.

Background: Ultrasound imaging at a low mechanical index and frame rate (10 to 20 Hz) after intravenous injections of perfluorocarbon containing microbubbles has the potential to evaluate myocardial perfusion and wall motion (WVM) simultaneously and in real time.

Methods: One hundred consecutive patients with intermediate-to-high probability of coronary artery disease underwent treadmill (n = 50) or supine bicycle (n = 50) exercise echocardiography. Segmental perfusion with MCE and WM w ere assessed in real time before and at peak exercise using low mechanical index (0.3) and frame rates of 10 to 20 Hz after 0.3 ml bolus injections of intravenous Optison (Mallinckrodt Inc., San Diego, California). All patients had a dual isotope (rest thallium-201, stress sestamibi) study performed during the same exercise session, and 44 patients had subsequent quantitative coronary angiography.

Results: In the 100 patients, agreement between MCE and single photon emission computed tomography (SPECT) was 76%, while it was 88% between MCE and WM assessment. Compared with quantitative angiography, sensitivity of MCE, SPECT and WM was comparable (75%), with a specificity ranging from 81% to 100%. The combination of MCE and WM had the best balance between sensitivity and specificity (86% and 88%,respectively) with the highest accuracy (86%).

Conclusions: The real-time assessment of myocardial perfusion during exercise stress echocardiography can be achieved with imaging at low mechanical index and frame rates. The combination of WM and MCE correlates well with SPECT and is a promising important addition to conventional stress echocardiography.

PubMed Disclaimer

Publication types

LinkOut - more resources