Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2001 Sep-Oct;7(5):421-6.

Short-course, intensity-modulated radiotherapy for localized prostate cancer

Affiliations
  • PMID: 11693901
Comparative Study

Short-course, intensity-modulated radiotherapy for localized prostate cancer

P A Kupelian et al. Cancer J. 2001 Sep-Oct.

Abstract

Purpose: The purpose of this study was to compare the toxicity, particularly rectal, between short-course, intensity-modulated radiotherapy (SCIM-RT) delivering 70 Gy in 28 fractions and three-dimensional conformal radiotherapy (3D-CRT) delivering 78 Gy in 39 fractions.

Materials and methods: A total of 191 patients were treated with SCIM-RT. Seventy Gy was delivered using five intensity-modulated fields via a Varian dynamic multileaf collimator. The BAT transabdominal ultrasound system was used for localization. The comparison group consisted of 101 contemporary cases treated with 3D-CRT to 78.0 Gy (2.0 Gy per fraction). The study sample therefore comprised 292 cases. Seventy Gy in 28 fractions was equivalent to 78 Gy in 39 fractions for late-reacting tissues, according to the linear quadratic model. The median follow-up was 9 months. Radiation Therapy Oncology Group toxicity scores were used.

Results: The rates of acute rectal Radiation Therapy Oncology Group toxicity scores 0, 1, 2, and 3 were 30%, 55%, 14%, and 0%, respectively, with SCIM-RT, versus 14%, 67%, 19%, and 0%, respectively, with 3D-CRT. The rates of acute urinary toxicity scores 0, 1, 2, and 3 were 17%, 62%, 20%, and 1%, respectively, with SCIM-RT, versus 22%, 58%, 20%, and 0%, respectively, with 3D-CRT. To date, only two patients who underwent SCIM-RT had grade 2 late urinarytoxicity. No grade 3 late urinary or rectal complications occurred with SCIM-RT. The actuarial late rectal grade 2 toxicity observed at 18 months was 10% after SCIM-RT, versus 12% after 3D-CRT. Only three patients had grade 3 late rectal toxicity; all of them had undergone 3D-CRT. A multivariate analysis of factors affecting grade 2-3 late rectal toxicity was performed by use of the following: age (continuous), race (black vs white), androgen deprivation (yes vs no), technique (SCIM-RT vs 3D-CRT), grade 2-3 acute rectal toxicity (yes vs no), and volume of rectum receiving the prescription dose (VrPr) (< or = 15 mL vs >15 mL). Only the VrPr was a significant independent factor predicting grade 2-3 late rectal toxicity. Only 15 SCIM-RT (7%) and 20 3D-CRT cases (20%) had a VrPr > 15 mL. With SCIM-RT, the grade 2-3 late rectal toxicity rate at 18 months with a VrPr > 15 mL was 29%, versus 5% with a VrPr < or = 15 mL. With 3D-CRT, the grade 2-3 late rectal toxicity rate at 18 months with a VrPr > 15 mL was 25%, versus 8% with a VrPr < or = 15 mL.

Conclusions: SCIM-RT, delivering 70.0 Gy at 2.5 Gy per fraction, had an acute and late toxicity profile up to 18 months after therapy that was similarto that of 3D-CRT delivering 78.0 Gy at 2.0 Gy per fraction. The grade 2 actuarial combined rectal toxicity rate is low (10%) at 18 months, although it increased when rectal volumes > 15 mL received 70 Gy with SCIM-RT. Only 7% of SCIM-RT cases received 70 Gy to > 15 ml of the rectum. If longer follow-up confirms the low late toxicity rates, SCIM-RT will be an alternative and more convenient method of dose-escalation in the treatment of localized prostate cancer.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources