Ductal lavage for detection of cellular atypia in women at high risk for breast cancer
- PMID: 11698566
- DOI: 10.1093/jnci/93.21.1624
Ductal lavage for detection of cellular atypia in women at high risk for breast cancer
Abstract
Background: Breast cancer originates in breast epithelium and is associated with progressive molecular and morphologic changes. Women with atypical breast ductal epithelial cells have an increased relative risk of breast cancer. In this study, ductal lavage, a new procedure for collecting ductal cells with a microcatheter, was compared with nipple aspiration with regard to safety, tolerability, and the ability to detect abnormal breast epithelial cells.
Methods: Women at high risk for breast cancer who had nonsuspicious mammograms and clinical breast examinations underwent nipple aspiration followed by lavage of fluid-yielding ducts. All statistical tests were two-sided.
Results: The 507 women enrolled included 291 (57%) with a history of breast cancer and 199 (39%) with a 5-year Gail risk for breast cancer of 1.7% or more. Nipple aspirate fluid (NAF) samples were evaluated cytologically for 417 women, and ductal lavage samples were evaluated for 383 women. Adequate samples for diagnosis were collected from 111 (27%) and 299 (78%) women, respectively. A median of 13,500 epithelial cells per duct (range, 43-492,000 cells) was collected by ductal lavage compared with a median of 120 epithelial cells per breast (range, 10-74,300) collected by nipple aspiration. For ductal lavage, 92 (24%) subjects had abnormal cells that were mildly (17%) or markedly (6%) atypical or malignant (<1%). For NAF, corresponding percentages were 6%, 3%, and fewer than 1%. Ductal lavage detected abnormal intraductal breast cells 3.2 times more often than nipple aspiration (79 versus 25 breasts; McNemar's test, P<.001). No serious procedure-related adverse events were reported.
Conclusions: Large numbers of ductal cells can be collected by ductal lavage to detect atypical cellular changes within the breast. Ductal lavage is a safe and well-tolerated procedure and is a more sensitive method of detecting cellular atypia than nipple aspiration.
Similar articles
-
Patterns of reduced nipple aspirate fluid production and ductal lavage cellularity in women at high risk for breast cancer.Breast Cancer Res. 2005;7(6):R1017-22. doi: 10.1186/bcr1335. Epub 2005 Oct 24. Breast Cancer Res. 2005. PMID: 16280052 Free PMC article.
-
Nipple aspirate fluid cytology in breast carcinoma.Cancer. 2003 Apr 25;99(2):97-104. doi: 10.1002/cncr.10958. Cancer. 2003. PMID: 12704689
-
Patient variables that predict atypical cytology by nipple duct lavage.Cancer. 2007 Apr 1;109(7):1247-54. doi: 10.1002/cncr.22538. Cancer. 2007. PMID: 17326050
-
Lavage and nipple aspiration of breast ductal fluids: a source of biomarkers for environmental mutagenesis.Environ Mol Mutagen. 2002;39(2-3):127-33. doi: 10.1002/em.10061. Environ Mol Mutagen. 2002. PMID: 11921180 Review.
-
Ductal lavage for breast cancer risk assessment.Cancer Control. 2002 Nov-Dec;9(6):473-9. doi: 10.1177/107327480200900604. Cancer Control. 2002. PMID: 12514565 Review.
Cited by
-
Breast cancer: new technologies for risk assessment and diagnosis.Mol Diagn. 2003;7(1):49-55. doi: 10.1007/BF03260021. Mol Diagn. 2003. PMID: 14529321 Review.
-
Tolerability of breast ductal lavage in women from families at high genetic risk of breast cancer.BMC Womens Health. 2009 Jul 14;9:20. doi: 10.1186/1472-6874-9-20. BMC Womens Health. 2009. PMID: 19602282 Free PMC article.
-
Characteristics of Breast Ducts in Normal-Risk and High-risk Women and Their Relationship to Ductal Cytologic Atypia.Cancer Prev Res (Phila). 2020 Dec;13(12):1027-1036. doi: 10.1158/1940-6207.CAPR-19-0305. Epub 2020 Aug 4. Cancer Prev Res (Phila). 2020. PMID: 32753377 Free PMC article.
-
Patterns of reduced nipple aspirate fluid production and ductal lavage cellularity in women at high risk for breast cancer.Breast Cancer Res. 2005;7(6):R1017-22. doi: 10.1186/bcr1335. Epub 2005 Oct 24. Breast Cancer Res. 2005. PMID: 16280052 Free PMC article.
-
Nipple aspirate fluid and its use for the early detection of breast cancer.Ann Med Surg (Lond). 2022 Apr 18;77:103625. doi: 10.1016/j.amsu.2022.103625. eCollection 2022 May. Ann Med Surg (Lond). 2022. PMID: 35638006 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical