Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2001 Nov 7;93(21):1624-32.
doi: 10.1093/jnci/93.21.1624.

Ductal lavage for detection of cellular atypia in women at high risk for breast cancer

Affiliations
Comparative Study

Ductal lavage for detection of cellular atypia in women at high risk for breast cancer

W C Dooley et al. J Natl Cancer Inst. .

Abstract

Background: Breast cancer originates in breast epithelium and is associated with progressive molecular and morphologic changes. Women with atypical breast ductal epithelial cells have an increased relative risk of breast cancer. In this study, ductal lavage, a new procedure for collecting ductal cells with a microcatheter, was compared with nipple aspiration with regard to safety, tolerability, and the ability to detect abnormal breast epithelial cells.

Methods: Women at high risk for breast cancer who had nonsuspicious mammograms and clinical breast examinations underwent nipple aspiration followed by lavage of fluid-yielding ducts. All statistical tests were two-sided.

Results: The 507 women enrolled included 291 (57%) with a history of breast cancer and 199 (39%) with a 5-year Gail risk for breast cancer of 1.7% or more. Nipple aspirate fluid (NAF) samples were evaluated cytologically for 417 women, and ductal lavage samples were evaluated for 383 women. Adequate samples for diagnosis were collected from 111 (27%) and 299 (78%) women, respectively. A median of 13,500 epithelial cells per duct (range, 43-492,000 cells) was collected by ductal lavage compared with a median of 120 epithelial cells per breast (range, 10-74,300) collected by nipple aspiration. For ductal lavage, 92 (24%) subjects had abnormal cells that were mildly (17%) or markedly (6%) atypical or malignant (<1%). For NAF, corresponding percentages were 6%, 3%, and fewer than 1%. Ductal lavage detected abnormal intraductal breast cells 3.2 times more often than nipple aspiration (79 versus 25 breasts; McNemar's test, P<.001). No serious procedure-related adverse events were reported.

Conclusions: Large numbers of ductal cells can be collected by ductal lavage to detect atypical cellular changes within the breast. Ductal lavage is a safe and well-tolerated procedure and is a more sensitive method of detecting cellular atypia than nipple aspiration.

PubMed Disclaimer

Similar articles

Cited by

Publication types