Implanted electrochemical glucose sensors for the management of diabetes
- PMID: 11701486
- DOI: 10.1146/annurev.bioeng.1.1.153
Implanted electrochemical glucose sensors for the management of diabetes
Abstract
By maintaining a near normal (70-120 mg/dL) glucose concentration, diabetic patients can drastically reduce the likelihood of the occurrence of diabetes complications. In the near future, subcutaneously implanted electrochemical glucose sensors will be available to provide frequent or continuous information on which timely treatment decisions, such as insulin injection or glucose source intake, can be based, as well as timely alarm signals. The currently engineered devices are of three types: (a) innocuous microsensors, with actively mass-transporting areas < 10(-3) cm2, replaced twice a week by the patient; (b) self-contained, surgeon-implanted, transmitter-containing packages of > 1 cm2 area, operating for > 100 days; and (c) devices transporting subcutaneous fluid to an external sensor, based on implanted microfiltration or microdialysis fibers or on iontophoretic transport of the subcutaneous fluid through the skin.
Similar articles
-
[Subcutaneously implantable glucose sensors in patients with diabetes mellitus; still many problems].Ned Tijdschr Geneeskd. 2002 Jul 13;146(28):1313-6. Ned Tijdschr Geneeskd. 2002. PMID: 12148218 Review. Dutch.
-
Developing glucose sensors for in vivo use.Trends Biotechnol. 1993 Jul;11(7):285-91. doi: 10.1016/0167-7799(93)90016-3. Trends Biotechnol. 1993. PMID: 7763951
-
Evaluation of subcutaneously-implanted glucose sensors for continuous glucose measurements in hyperglycemic pigs.In Vivo. 2006 Mar-Apr;20(2):195-203. In Vivo. 2006. PMID: 16634519
-
Enzymatic glucose sensors. Improved long-term performance in vitro and in vivo.ASAIO J. 1994 Apr-Jun;40(2):157-63. ASAIO J. 1994. PMID: 8003752
-
[Biosensors for continuous glucose and lactate monitoring].Ned Tijdschr Geneeskd. 2003 Jun 21;147(25):1204-8. Ned Tijdschr Geneeskd. 2003. PMID: 12848054 Review. Dutch.
Cited by
-
Comparison between one-point calibration and two-point calibration approaches in a continuous glucose monitoring algorithm.J Diabetes Sci Technol. 2014 Jul;8(4):709-19. doi: 10.1177/1932296814531356. Epub 2014 Apr 21. J Diabetes Sci Technol. 2014. PMID: 24876420 Free PMC article.
-
All-plastic electrochemical transistor for glucose sensing using a ferrocene mediator.Sensors (Basel). 2009;9(12):9896-902. doi: 10.3390/s91209896. Epub 2009 Dec 4. Sensors (Basel). 2009. PMID: 22303153 Free PMC article.
-
Modular coupling MOF nanozyme with natural enzyme on hollow fiber membrane for rapid and reusable detection of H2O2 and glucose.Mikrochim Acta. 2024 Jan 19;191(2):107. doi: 10.1007/s00604-023-06150-x. Mikrochim Acta. 2024. PMID: 38240908
-
Layer-by-layer assembled semipermeable membrane for amperometric glucose sensors.J Diabetes Sci Technol. 2007 Mar;1(2):193-200. doi: 10.1177/193229680700100209. J Diabetes Sci Technol. 2007. PMID: 19888406 Free PMC article.
-
Protein-based biosensors for diabetic patients.J Fluoresc. 2004 Sep;14(5):491-8. doi: 10.1023/b:jofl.0000039337.30726.6d. J Fluoresc. 2004. PMID: 15617257