Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2001 Sep;20(9):626-35.
doi: 10.1007/s100960100574.

Multicenter evaluation of an automated system using selected bacteria that harbor challenging and clinically relevant mechanisms of resistance to antibiotics

Affiliations
Comparative Study

Multicenter evaluation of an automated system using selected bacteria that harbor challenging and clinically relevant mechanisms of resistance to antibiotics

R Leclercq et al. Eur J Clin Microbiol Infect Dis. 2001 Sep.

Abstract

A multicenter study was carried out to evaluate the performance of a new commercial automated system in comparison with that of the reference agar dilution method. Ten clinical microbiology laboratories tested a collection of 61 strains of gram-negative bacilli (49 Enterobacteriaceae and 12 Pseudomonas aeruginosa), and 6 other laboratories tested a collection of 55 strains of gram-positive cocci (10 enterococci and 45 staphylococci) against 10-20 antimicrobial agents. The strains were selected on the basis that they harbored challenging and characterized mechanisms of resistance. In comparison with the agar reference method, the automated system gave an overall essential agreement (+/-1 dilution) of 94.5%, 93.5%, and 97% for the gram-negative bacilli, enterococci, and staphylococci, respectively. According to the interpretive standards of the National Committee for Clinical Laboratory Standards, the category agreement ranged from 96 to 96.4% for the three sets of organisms. The accuracy of the automated system, as determined by the kappa test, ranged from 0.80 to 0.88, reflecting an almost perfect agreement with the reference technique. Very major, major, and minor errors obtained with the automated system were 0.3%, 2.9%, and 6.6% for gram-negative bacilli, 3.4%, 0%, and 5% for enterococci, and 1%, 1.6%, and 2.7% for staphylococci, respectively. The high rate of very major errors in enterococci was mostly due to a single strain of multidrug-resistant Enterococcus faecium, which was found susceptible to several antibiotics in a majority of participant laboratories. The use of a heavy inoculum and of a broth test medium by the automated system might account for a better expression of certain resistance mechanisms, including beta-lactamases, as compared to the agar dilution reference method. The interlaboratory reproducibility was acceptable, as shown by the narrow dispersion of MICs and by the results of quality control.

PubMed Disclaimer

MeSH terms

Substances

LinkOut - more resources