[Method for the continuous measurement of the phase relation between heart beat and respiration (author's transl)]
- PMID: 1171429
- DOI: 10.1007/BF00584801
[Method for the continuous measurement of the phase relation between heart beat and respiration (author's transl)]
Abstract
A simple method for the continuous analysis of the phase relation between heart beat and respiration is described. By means of an analog computer the timing of the R wave of the ECG within the respiratory cycle is graphically displayed. In contrast to other investigations, the onset of the inspiration is used as starting signal. The results obtained with the analog computer were completed by a digital computer program, which allowed in addition to calculate histograms of the events. In order to evaluate our method we used an analog model of two coupled oscillators. Responses obtained at different coupling characteristics were compared with measurements in four subjects. The results indicate a mutual interaction between heart action and respiration as cause of the coupling of these two systems.
Similar articles
-
[Real time measurement of myocardial contractility by an analog computer with digital displays for each successive beat (author's transl)].Iyodenshi To Seitai Kogaku. 1978 Aug;16(4):274-5. Iyodenshi To Seitai Kogaku. 1978. PMID: 722973 Japanese. No abstract available.
-
[Continuous analysis of the pulse rate during long-term ECG recordings with the aid of a process computer. Draft of programme for the correction of faulty pulse periods (due to stress situations) (author's transl)].Int Arch Arbeitsmed. 1973 May 23;31(2):105-22. Int Arch Arbeitsmed. 1973. PMID: 4751370 German. No abstract available.
-
Cardiorespiratory coupling in young healthy subjects.Physiol Meas. 2017 Nov 30;38(12):2186-2202. doi: 10.1088/1361-6579/aa9693. Physiol Meas. 2017. PMID: 29076810
-
In vivo cardiac phase response curve elucidates human respiratory heart rate variability.Nat Commun. 2013;4:2418. doi: 10.1038/ncomms3418. Nat Commun. 2013. PMID: 23995013
-
Development of three methods for extracting respiration from the surface ECG: a review.J Electrocardiol. 2014 Nov-Dec;47(6):819-25. doi: 10.1016/j.jelectrocard.2014.07.020. Epub 2014 Aug 4. J Electrocardiol. 2014. PMID: 25194875 Review.
Cited by
-
Method for the analysis of the entrainment between heart rate and ventilation rate.Pflugers Arch. 1976 Jun 22;363(3):263-5. doi: 10.1007/BF00594612. Pflugers Arch. 1976. PMID: 986612
-
A quantitative comparison of different methods to detect cardiorespiratory coordination during night-time sleep.Biomed Eng Online. 2004 Nov 25;3(1):44. doi: 10.1186/1475-925X-3-44. Biomed Eng Online. 2004. PMID: 15563735 Free PMC article.
-
Cardio-respiratory coordination increases during sleep apnea.PLoS One. 2014 Apr 9;9(4):e93866. doi: 10.1371/journal.pone.0093866. eCollection 2014. PLoS One. 2014. PMID: 24718564 Free PMC article.