The evaluation of clotting times in the laboratory detection of lupus anticoagulants
- PMID: 11728529
- DOI: 10.1016/s0049-3848(01)00365-6
The evaluation of clotting times in the laboratory detection of lupus anticoagulants
Abstract
Although there is international consensus regarding the general principles of testing for lupus anticoagulants (LAs), no agreement exists as far as the analysis of the clotting time results is concerned. Twenty-nine laboratories participating in the Fifth International Survey of Lupus Anticoagulants (ISLA-5) reported the activated partial thromboplastin time (APTT)-based clotting times obtained on seven defined test samples and a normal plasma (NP) using the same two reagents with low and high phospholipid (PL) concentrations, respectively. These clotting times were used to analyse how various methods of calculating the results may influence the apparent sensitivity of LA tests. We found that the use of a separate screening test may lead to the exclusion of samples where the presence of LA would have been detected by a combined screening and confirmatory method. For instance, the dilute APTT (dAPTT) gave a sensitivity of 53.5% (screening test), while the calculation of a ratio between the clotting times obtained with two different PL concentrations gave a sensitivity of 68.1% (confirmatory test). The normalisation of results by dividing with the corresponding results of NP increased the apparent sensitivity. The screening test ratio between dAPTT results of test samples and NP gave a sensitivity of 84.7%. The normalised ratio between the clotting times obtained with the two reagents (lupus ratio, LR) gave a sensitivity of 95.1%. We conclude that when testing for LA, all samples should be tested with both low (screening procedure) and high (confirmatory procedure) PL concentrations. These two clotting times should be evaluated in relation to each other and to the corresponding results obtained with a reference plasma (normalisation).
Similar articles
-
The Lupus Ratio test--an interlaboratory study on the detection of Lupus anticoagulants by an APTT-based, integrated, and semi-quantitative test. Fifth International Survey of Lupus Anticoagulants--ISLA 5.Thromb Haemost. 2000 May;83(5):704-8. Thromb Haemost. 2000. PMID: 10823266
-
Dilute prothrombin time-based lupus ratio test. Integrated LA testing with recombinant tissue thromboplastin.Thromb Res. 2002 Jan 15;105(2):177-82. doi: 10.1016/s0049-3848(01)00420-0. Thromb Res. 2002. PMID: 11958810
-
Laboratory heterogeneity of the lupus anticoagulant: a multicentre study using different clotting assays on a panel of 78 samples. Hemostasis Committee of the "Société Française de Biologie Clinique".Thromb Res. 1992 May 15;66(4):349-64. doi: 10.1016/0049-3848(92)90284-h. Thromb Res. 1992. PMID: 1412201
-
Laboratory identification of lupus anticoagulants.Semin Thromb Hemost. 2012 Jun;38(4):375-84. doi: 10.1055/s-0032-1311991. Epub 2012 May 9. Semin Thromb Hemost. 2012. PMID: 22573409 Review.
-
Screening for the lupus anticoagulant.Ric Clin Lab. 1989 Oct-Dec;19(4):379-89. doi: 10.1007/BF02871829. Ric Clin Lab. 1989. PMID: 2517352 Review.
Cited by
-
Detection and quantification of lupus anticoagulants in plasma from heparin treated patients, using addition of polybrene.Thromb J. 2006 Jan 25;4:3. doi: 10.1186/1477-9560-4-3. Thromb J. 2006. PMID: 16436199 Free PMC article.
-
The enigmas of the lupus anticoagulant: mechanisms, diagnosis, and management.Curr Rheumatol Rep. 2008 Jan;10(1):74-80. doi: 10.1007/s11926-008-0013-x. Curr Rheumatol Rep. 2008. PMID: 18457616 Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous