Field size reduction enables iso-NTCP escalation of tumor control probability for irradiation of lung tumors
- PMID: 11728689
- DOI: 10.1016/s0360-3016(01)01729-1
Field size reduction enables iso-NTCP escalation of tumor control probability for irradiation of lung tumors
Abstract
Purpose: With the mean lung dose (MLD) as an estimator for the normal tissue complication probability (NTCP) of the lung, we assessed whether the probability of tumor control of lung tumors might be increased by dose escalation in combination with a reduction of field sizes, thus increasing target dose inhomogeneity while maintaining a constant MLD.
Methods and materials: An 8-MV AP-PA irradiation of a lung tumor, located in a cylindrically symmetric lung-equivalent phantom, was modeled using numerical simulation. Movement of the clinical target volume (CTV) due to patient breathing and setup errors was simulated. The probability of tumor control, expressed as the equivalent uniform dose (EUD) of the CTV, was assessed as a function of field size, under the constraint of a constant MLD. The approach was tested for a treatment of a non-small cell lung cancer (NSCLC) patient using the beam directions of the clinically applied treatment plan.
Results: In the phantom simulation it was shown that by choosing field sizes that ensured a minimum dose of 95% in the CTV ("conventional" plan) taking into account setup errors and tumor motion, an EUD of the CTV of 43.8 Gy can be obtained for a prescribed dose of 44.2 Gy. By reducing the field size and thus shifting the 95% isodose surface inwards, the EUD increases to a maximum of 68.3 Gy with a minimum dose in the CTV of 55.2 Gy. This increase in EUD is caused by the fact that field size reduction enables escalation of the prescribed dose while maintaining a constant MLD. Further reduction of the field size results in decrease of the EUD because the minimum dose in the CTV becomes so low that it has a predominant effect on the EUD, despite further escalation of the prescribed dose. For the NSCLC patient, the EUD could be increased from an initial 62.2 Gy for the conventional plan, to 83.2 Gy at maximum. In this maximum, the prescribed dose is 88.1 Gy, and the minimum dose in the CTV is 67.4 Gy. In this case, the 95% isodose surface is conformed closely to the "static" CTV during treatment planning.
Conclusions: Iso-NTCP escalation of the probability of tumor control is possible for lung tumors by reducing field sizes and allowing a larger dose inhomogeneity in the CTV. Optimum field sizes can be derived, having the highest EUD and highest minimum dose in the CTV under condition of a constant NTCP of the lungs. We conclude that the concept of homogeneous dose in the target volume is not the best approach to reach the highest probability of tumor control for lung tumors.
Similar articles
-
The theoretical benefit of beam fringe compensation and field size reduction for iso-normal tissue complication probability dose escalation in radiotherapy of lung cancer.Med Phys. 2003 Jun;30(6):1086-95. doi: 10.1118/1.1573208. Med Phys. 2003. PMID: 12852532
-
The effect of breathing and set-up errors on the cumulative dose to a lung tumor.Radiother Oncol. 2001 Jul;60(1):95-105. doi: 10.1016/s0167-8140(01)00349-8. Radiother Oncol. 2001. PMID: 11410310
-
Target volume dose considerations in proton beam treatment planning for lung tumors.Med Phys. 2005 Dec;32(12):3549-57. doi: 10.1118/1.2126187. Med Phys. 2005. PMID: 16475753
-
The effect on minimum tumor dose of restricting target-dose inhomogeneity in optimized three-dimensional treatment of lung cancer.Radiother Oncol. 1991 Aug;21(4):245-56. doi: 10.1016/0167-8140(91)90049-m. Radiother Oncol. 1991. PMID: 1924862 Review.
-
Biological aspects of conformal therapy.Acta Oncol. 2000;39(5):569-77. doi: 10.1080/028418600750013258. Acta Oncol. 2000. PMID: 11093365 Review.
Cited by
-
(Radio)biological optimization of external-beam radiotherapy.Comput Math Methods Med. 2012;2012:329214. doi: 10.1155/2012/329214. Epub 2012 Nov 6. Comput Math Methods Med. 2012. PMID: 23251227 Free PMC article.
-
Radiobiologically guided optimisation of the prescription dose and fractionation scheme in radiotherapy using BioSuite.Br J Radiol. 2012 Sep;85(1017):1279-86. doi: 10.1259/bjr/20476567. Epub 2012 Mar 28. Br J Radiol. 2012. PMID: 22457318 Free PMC article.
-
Beyond the margin recipe: the probability of correct target dosage and tumor control in the presence of a dose limiting structure.Phys Med Biol. 2017 Sep 20;62(19):7874-7888. doi: 10.1088/1361-6560/aa87fe. Phys Med Biol. 2017. PMID: 28832334 Free PMC article.
-
Influence of increased target dose inhomogeneity on margins for breathing motion compensation in conformal stereotactic body radiotherapy.BMC Med Phys. 2008 Dec 3;8:5. doi: 10.1186/1756-6649-8-5. BMC Med Phys. 2008. PMID: 19055768 Free PMC article.