The impact of FDG-PET on the management algorithm for recurrent colorectal cancer
- PMID: 11734912
- DOI: 10.1007/s002590100646
The impact of FDG-PET on the management algorithm for recurrent colorectal cancer
Abstract
Positron emission tomography (PET) has been successfully used to image colorectal cancer (CRC). This study evaluated the accuracy of 2-[(18)F]-fluoro-2-deoxy- D-glucose (FDG) PET for the detection and staging of recurrent CRC and the consequent impact on clinical management. Forty-two patients previously treated for CRC were investigated for suspected recurrence and, if recurrence was confirmed, the extent of disease was evaluated. All patients underwent whole-body FDG-PET and computed tomography (CT) scan and results were compared to assess sensitivity, specificity and diagnostic accuracy for each modality. We then assessed the FDG-PET directed alteration in clinical management from that planned on the basis of spiral CT results. FDG-PET was more sensitive (93%) than CT (73%) for detection of recurrence (specificity 58% and 75%, respectively). FDG-PET yielded a correct diagnosis in 35 (83%) out of 42 patients, while CT did so in 31 patients (74%). FDG-PET was more accurate than CT for staging local recurrence (sensitivity 100%, specificity 86% with FDG-PET vs 75% and 100%, respectively, with CT) and CRC liver metastases (sensitivity 100% vs 45%; specificity 100% for both). Overall, PET upstaged 8 out of 30 patients (27%) and altered patient management in 16 (38%) cases. This study confirms that FDG-PET is more sensitive than CT for the detection and staging of recurrent CRC. The results also indicate that FDG-PET is an accurate means of selecting appropriate patients for operative treatment. When applied to routine clinical practice, patient management is altered.
Similar articles
-
Clinical impact of fluorodeoxyglucose-positron emission tomography scan/computed tomography in comparison with computed tomography on the detection of colorectal cancer recurrence.Eur J Gastroenterol Hepatol. 2011 Mar;23(3):275-81. doi: 10.1097/MEG.0b013e328343eaa0. Eur J Gastroenterol Hepatol. 2011. PMID: 21304319
-
Detection of recurrent and metastatic colorectal cancer: comparison of positron emission tomography and computed tomography.Ann Surg Oncol. 1997 Dec;4(8):613-20. doi: 10.1007/BF02303744. Ann Surg Oncol. 1997. PMID: 9416407
-
[Evaluation of positron emission tomography by using F-18-fluorodeoxyglucose in diagnosis of recurrent colorectal cancer].Pol Merkur Lekarski. 2004;17 Suppl 1:63-6. Pol Merkur Lekarski. 2004. PMID: 15603351 Clinical Trial. Polish.
-
The clinical application of positron emission tomography to colorectal cancer management.Q J Nucl Med. 2001 Sep;45(3):215-30. Q J Nucl Med. 2001. PMID: 11788814 Review.
-
Role of FDG-PET in the diagnosis and treatment of colorectal liver metastases.Expert Rev Anticancer Ther. 2004 Aug;4(4):607-13. doi: 10.1586/14737140.4.4.607. Expert Rev Anticancer Ther. 2004. PMID: 15270664 Review.
Cited by
-
Positron emission tomography scanning is not superior to whole body multidetector helical computed tomography in the preoperative staging of colorectal cancer.Gut. 2006 Jul;55(7):1007-11. doi: 10.1136/gut.2005.076273. Epub 2005 Dec 16. Gut. 2006. PMID: 16361308 Free PMC article.
-
Value of 18F-FDG PET in the detection of peritoneal carcinomatosis.Eur J Nucl Med Mol Imaging. 2004 Oct;31(10):1413-20. doi: 10.1007/s00259-004-1577-y. Epub 2004 Jun 16. Eur J Nucl Med Mol Imaging. 2004. PMID: 15205922 Clinical Trial.
-
FDG-PET scan in patients with clinically and/or radiologically suspicious colorectal cancer recurrence but normal CEA.World J Surg Oncol. 2007 Jun 7;5:64. doi: 10.1186/1477-7819-5-64. World J Surg Oncol. 2007. PMID: 17555577 Free PMC article.
-
Variation in positron emission tomography use after colon cancer resection.J Oncol Pract. 2015 May;11(3):e363-72. doi: 10.1200/JOP.2014.001933. Epub 2015 Apr 7. J Oncol Pract. 2015. PMID: 25852143 Free PMC article.
-
Late sacral recurrence of rectal cancer treated by heavy ion radiotherapy: a case report.Surg Case Rep. 2016 Dec;2(1):109. doi: 10.1186/s40792-016-0240-8. Epub 2016 Oct 10. Surg Case Rep. 2016. PMID: 27726113 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical