[Interstitial T1-weighted MR lymphography with use of the dendritic contrast agent Gadomer-17 in pigs]
- PMID: 11740675
- DOI: 10.1055/s-2001-18891
[Interstitial T1-weighted MR lymphography with use of the dendritic contrast agent Gadomer-17 in pigs]
Abstract
Purpose: To investigate the enhancement of regional lymph nodes, lymph vessels and the thoracic duct after subcutaneous administration of the dendritic contrast agent Gadomer-17.
Materials and methods: Interstitial T(1)-weighted MR lymphography was performed in 15 domestic pigs in a 1.5 T MR scanner using the body coil. The contrast agent was injected subcutaneously at a dose of 2.5, 10 and 20 micromol gadolinium/kg/bw (1.4 - 2.3 ml) in the hind legs of 5 pigs, respectively. T(1)-weighted coronal 3D-gradient-echo images were obtained 1 to 150 minutes and 24 hours after contrast material injection.
Results: Inguinal lymph nodes, iliac lymph nodes and lymph vessels showed peak enhancement within 10 minutes after subcutaneous administration of the contrast agent. The enhancement of the lymphatic system decreased slowly until 150 minutes post injection. The time-response study, which was performed for inguinal and iliac lymph nodes, revealed the best lymphographic effect for Gadomer-17 at a dose of 10 micromol gadolinium/kg/bw. At this dose the paraaortic lymph nodes and the thoracic duct were also best visualized.
Conclusion: Interstitial administration of the evaluated dendritic contrast agent Gadomer-17 is highly efficient for the performance of T(1)-weighted MR lymphography in regional lymph nodes, lymph vessels and the thoracic duct.
Similar articles
-
T1-weighted MR-lymphography after intramammary administration of Gadomer-17 in pigs.Rofo. 2002 Jan;174(1):29-32. doi: 10.1055/s-2002-19551. Rofo. 2002. PMID: 11793281
-
[High-resolution T1-weighted MR-lymphography of inguinal lymph nodes after interstitial application of Gadomer-17 in animal experiments].Rofo. 2005 Jul;177(7):968-74. doi: 10.1055/s-2005-858239. Rofo. 2005. PMID: 15973599 German.
-
[Interstitial T1-weighted MR lymph fistulography with Gadomer-17 in an experimental animal model].Rofo. 2003 Feb;175(2):275-81. doi: 10.1055/s-2003-37231. Rofo. 2003. PMID: 12584631 German.
-
MR contrast agents in lymph node imaging.Eur J Radiol. 2006 Jun;58(3):375-82. doi: 10.1016/j.ejrad.2005.12.044. Epub 2006 Feb 7. Eur J Radiol. 2006. PMID: 16464554 Review.
-
[Contrast media for magnetic resonance tomographic lymph node diagnosis (MR lymphography)].Radiologe. 1996 Feb;36(2):134-40. doi: 10.1007/s001170050050. Radiologe. 1996. PMID: 8867430 Review. German.
Cited by
-
Contrast-enhanced MR imaging of lymph nodes in cancer patients.Korean J Radiol. 2010 Jul-Aug;11(4):383-94. doi: 10.3348/kjr.2010.11.4.383. Epub 2010 Jun 21. Korean J Radiol. 2010. PMID: 20592922 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical