The return of the frequency sweep: designing adiabatic pulses for contemporary NMR
- PMID: 11740891
- DOI: 10.1006/jmre.2001.2340
The return of the frequency sweep: designing adiabatic pulses for contemporary NMR
Abstract
Frequency-modulated (FM) pulses that function according to adiabatic principles are becoming increasingly popular in many areas of NMR. Often adiabatic pulses can extend experimental capabilities and minimize annoying experimental imperfections. Here, adiabatic principles and some of the current methods used to create these pulses are considered. The classical adiabatic rapid passage, which is a fundamental element upon which all adiabatic pulses and sequences are based, is analyzed using vector models in different rotating frames of reference. Two methods to optimize adiabaticity are described, and ways to tailor modulation functions to best satisfy specific experimental needs are demonstrated. Finally, adiabatic plane rotation pulses and frequency-selective multiple spin-echo sequences are considered.
Similar articles
-
Fast broadband inversion by adiabatic pulses.J Magn Reson. 1998 Jul;133(1):200-3. doi: 10.1006/jmre.1998.1441. J Magn Reson. 1998. PMID: 9654487
-
Diffusion damping during adiabatic z-rotation pulses for NMR spectroscopy in inhomogeneous magnetic fields.J Chem Phys. 2006 Jul 28;125(4):44503. doi: 10.1063/1.2219438. J Chem Phys. 2006. PMID: 16942152
-
Asymmetric adiabatic pulses for NH selection.J Magn Reson. 1999 May;138(1):173-7. doi: 10.1006/jmre.1999.1713. J Magn Reson. 1999. PMID: 10329242
-
Adiabatic pulses.NMR Biomed. 1997 Dec;10(8):423-34. doi: 10.1002/(sici)1099-1492(199712)10:8<423::aid-nbm488>3.0.co;2-x. NMR Biomed. 1997. PMID: 9542739 Review.
-
Exchange-influenced T2rho contrast in human brain images measured with adiabatic radio frequency pulses.Magn Reson Med. 2005 Apr;53(4):823-9. doi: 10.1002/mrm.20428. Magn Reson Med. 2005. PMID: 15799068
Cited by
-
Regional sex differences in neurochemical profiles of healthy mice measured by magnetic resonance spectroscopy at 9.4 tesla.Front Neurosci. 2023 Oct 25;17:1278828. doi: 10.3389/fnins.2023.1278828. eCollection 2023. Front Neurosci. 2023. PMID: 37954878 Free PMC article.
-
What is the optimal schedule for multiparametric MRS? A magnetic resonance fingerprinting perspective.NMR Biomed. 2021 May;34(5):e4196. doi: 10.1002/nbm.4196. Epub 2019 Dec 9. NMR Biomed. 2021. PMID: 31814197 Free PMC article.
-
Capturing exchange using periodic radiofrequency irradiation.J Magn Reson. 2018 Nov;296:79-84. doi: 10.1016/j.jmr.2018.09.001. Epub 2018 Sep 5. J Magn Reson. 2018. PMID: 30223154 Free PMC article.
-
Relaxation anisotropy of quantitative MRI parameters in biological tissues.Sci Rep. 2022 Jul 15;12(1):12155. doi: 10.1038/s41598-022-15773-8. Sci Rep. 2022. PMID: 35840627 Free PMC article.
-
Towards 1H-MRSI of the human brain at 7T with slice-selective adiabatic refocusing pulses.MAGMA. 2008 Mar;21(1-2):95-101. doi: 10.1007/s10334-007-0094-y. Epub 2008 Jan 22. MAGMA. 2008. PMID: 18210177 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources