Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2002 Jan;59(1):46-55.
doi: 10.1002/jbm.1215.

Quantifying adhesive penetration in adhesive/dentin interface using confocal Raman microspectroscopy

Affiliations

Quantifying adhesive penetration in adhesive/dentin interface using confocal Raman microspectroscopy

Yong Wang et al. J Biomed Mater Res. 2002 Jan.

Abstract

Confocal Raman microspectroscopy (CRM) provides an important and novel means of analyzing the chemical composition of the adhesive/dentin (a/d) interface. The purpose of this study was to develop a method for quantitative determination of the degree of adhesive penetration at the a/d interface using CRM. Three commercial dentin adhesive systems [Scotchbond Multipurpose Plus (SBMP+), Single Bond (SB), and Primer Bond NT (PBNT)] based on the total etch and "wet" bonding technique were examined in this study. Human dentin specimens treated with these adhesives were analyzed with CRM mapping across the a/d interface. Also, Raman spectra were collected on model mixtures of adhesive and type I collagen, and the ratios of the relative intensities of the Raman bands corresponding to adhesive and collagen were used for the construction of calibration curves. By comparing the Raman band ratios of interface specimens to the calibration curves, the percent of adhesive as a function of spatial position across the a/d interface was determined. The results show that there is a gradual decrease in penetration as a function of position for all three adhesive systems while the adhesive concentration gradient decreases in the order of SBMP+ > SB > PBNT. These differences in penetration of the three adhesives at the a/d interface also are discussed relative to the composition and phase segregation in adhesives. Additionally, our results indicate that confocal Raman microspectroscopy is a reliable in situ analytical technique for simple and rapid quantitative determination of adhesive penetration at its interface with prepared dentin.

PubMed Disclaimer

Publication types

LinkOut - more resources