Subarachnoidal hemorrhage following carotid stenting with the distal-balloon protection
- PMID: 11747193
- DOI: 10.1002/ccd.1324
Subarachnoidal hemorrhage following carotid stenting with the distal-balloon protection
Abstract
A 61-year-old man underwent carotid stenting with the distal-balloon protection system for symptomatic carotid artery stenosis. During the procedure, progressive elevation of the systolic blood pressure occurred, reaching a peak of 220 mm Hg immediately following deflation of the distal balloon. This was associated with severe headaches and progressive deterioration in the mental status to a coma. Head CT scan showed massive subarachnoidal hemorrhage contralateral to the stented side and a secondary intracerebral hemorrhage. Despite immediate successful blood pressure control, his condition deteriorated and he died 2 days later.
Copyright 2001 Wiley-Liss, Inc.
Comment in
-
Limiting the complications of carotid stenting.Catheter Cardiovasc Interv. 2001 Dec;54(4):524-5. doi: 10.1002/ccd.1325. Catheter Cardiovasc Interv. 2001. PMID: 11747194 No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources