Retention of maxillary implant overdenture bars of different designs
- PMID: 11753311
- DOI: 10.1067/mpr.2001.120838
Retention of maxillary implant overdenture bars of different designs
Abstract
Statement of problem: The specific degree of retention for overdenture attachments is unknown in relation to design, location, and alignment to supporting dental implants.
Purpose: The purpose of this study was to evaluate the initial retention characteristics of 5 implant maxillary overdenture designs under in vitro dislodging forces.
Material and methods: A simulated edentulous maxilla was fabricated with 4 screw-type 3.75 x 13-mm implants anteriorly. Five overdenture designs with the following attachments were evaluated: 4 plastic Hader clips with an EDS bar; 2 plastic anterior Hader clips with an identical EDS bar; 2 Hader clips with 2 posterior ERA attachments; 3 Zaag attachments on a bar; and 4 Zaag attachments with no bar. Overdentures were fabricated with full palatal coverage. Each design was subjected to 10 consecutive retention pulls on a universal testing machine. Data were subjected to analysis of variance and t tests to determine differences.
Results: The highest average value after 10 pulls was 19.8 lb for the combination ERA and Hader clip design. The lowest retentive values were recorded for the 2 and 4 Hader clip designs (5.08 +/- 0.89 lb and 5.06 +/- 0.67 lb, respectively). Retention decreased over the course of consecutive pulls for all designs, especially for the most retentive designs. The smallest retention decrease occurred with the least retentive designs.
Conclusion: The results of this in vitro study suggest that the precise selection and placement of attachments may affect the clinical success of maxillary implant-retained overdentures.
Similar articles
-
Photoelastic analysis of the effect of palatal support on various implant-supported overdenture designs.J Prosthet Dent. 2004 May;91(5):421-7. doi: 10.1016/S0022391304000927. J Prosthet Dent. 2004. PMID: 15153848
-
Retention of implant-supported overdenture with bar/clip and stud attachment designs.J Oral Implantol. 2013 Apr;39(2):140-7. doi: 10.1563/AAID-JOI-D-11-00016. Epub 2011 Sep 9. J Oral Implantol. 2013. PMID: 21905896
-
The service life of implant-retained overdenture attachment systems.J Prosthet Dent. 2009 Aug;102(2):74-80. doi: 10.1016/S0022-3913(09)60112-8. J Prosthet Dent. 2009. PMID: 19643220
-
In vivo force measurements on maxillary implants supporting a fixed prosthesis or an overdenture: a pilot study.J Prosthet Dent. 2000 Nov;84(5):535-47. doi: 10.1067/mpr.2000.110264. J Prosthet Dent. 2000. PMID: 11105009 Review.
-
Attachment systems for mandibular two-implant overdentures: a review of in vitro investigations on retention and wear features.Int J Prosthodont. 2009 Sep-Oct;22(5):429-40. Int J Prosthodont. 2009. PMID: 20095190 Review.
Cited by
-
In vitro retention force measurement for three different attachment systems for implant-retained overdenture.J Indian Prosthodont Soc. 2016 Oct-Dec;16(4):380-385. doi: 10.4103/0972-4052.191284. J Indian Prosthodont Soc. 2016. PMID: 27746603 Free PMC article.
-
The Influence of Cleaning Solutions on the Retention of Overdenture Attachment Systems.Biomedicines. 2023 Jun 9;11(6):1681. doi: 10.3390/biomedicines11061681. Biomedicines. 2023. PMID: 37371776 Free PMC article.
-
Comparison of retentive force and wear pattern of Locator® and ADD-TOC attachments combined with CAD-CAM milled bar.J Adv Prosthodont. 2022 Feb;14(1):12-21. doi: 10.4047/jap.2022.14.1.12. Epub 2022 Feb 25. J Adv Prosthodont. 2022. PMID: 35284053 Free PMC article.
-
Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.Saudi Dent J. 2013 Apr;25(2):53-60. doi: 10.1016/j.sdentj.2012.12.003. Epub 2013 Feb 6. Saudi Dent J. 2013. PMID: 23960557 Free PMC article.
-
Biomaterial aspects: A key factor in the longevity of implant overdenture attachment systems.J Int Soc Prev Community Dent. 2015 Jul-Aug;5(4):255-62. doi: 10.4103/2231-0762.161752. J Int Soc Prev Community Dent. 2015. PMID: 26312224 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials