. 2001 Dec;54(12):1406-10.
doi: 10.1016/s0300-8932(01)76523-2.

[Early deambulation following cardiac catheterization by the use of 6 Fr Angio-Seal, a new hemostatic percutaneous puncture closure device]

[Article in Spanish]
Affiliations
Free article
Clinical Trial

[Early deambulation following cardiac catheterization by the use of 6 Fr Angio-Seal, a new hemostatic percutaneous puncture closure device]

[Article in Spanish]
L S Díaz De La Llera et al. Rev Esp Cardiol. 2001 Dec.
Free article

Abstract

Introduction and objectives: Efficacy of the hemostatic puncture closure 8 Fr Angio-Seal device for percutaneous puncture closure after a catheterism has been previously demonstrated, but the experience provided has been obtained with 8 Fr devices. At present the device has been modified and its size reduced to 6 Fr. In this pilot study we evaluate the efficacy of the new hemostatic 6 Fr Angio-Seal device and its safety when early deambulation post-diagnostic and/or therapeutic catheterization is established.

Patients and methods: Prospective study of 150 consecutive patients randomized either for application of the 6 Fr Angio-Seal device (group A; n = 75), in which early ambulation was indicated, or manual compression (group B; n = 75), with ambulation 12 h after cardiac catheterization. Basal data, including clinical and angiographic characteristics and previous treatment with heparin and platelet aggregation inhibitors were similar in both groups.

Results: The time of hemostasia was significantly shorter in group A than in group B (118 +/- 210 s in A vs 1320 +/- 370 s in B; p (3/4) 0,001), and with early ambulation (3,1 +/- 0,4 h in A vs 12,3 +/- 3,1 h in B; p (3/4) 0,001) no local complications were observed.

Conclusions: The 6 Fr Angio-Seal hemostatic device diminished the hemostasia time and early ambulation could be achieved. In this pilot study no complications due to early movilization were observed, but the safety of the new hemostatic device after diagnostic or therapeutic catheterizations needs to be evaluated in greater series.