Acoustic noise reduction in a 4 T MRI scanner
- PMID: 11755093
- DOI: 10.1007/BF02678593
Acoustic noise reduction in a 4 T MRI scanner
Abstract
High-field, high-speed magnetic resonance imaging (MRI) can generate high levels of noise. There is ongoing concern in the medical and imaging research communities regarding the detrimental effects of high acoustic levels on auditory function, patient anxiety, verbal communication between patients and health care workers and ultimately MR image quality. In order to effectively suppress the noise levels inside MRI scanners, the sound field needs to be accurately measured and characterized. This paper presents the results of measurements of the sound radiation from a gradient coil cylinder within a 4 T MRI scanner under a variety of conditions. These measurement results show: (1) that noise levels can be significantly reduced through the use of an appropriately designed passive acoustic liner; and (2) the true noise levels that are experienced by patients during echo planar imaging.
Similar articles
-
MRI gradient coil cylinder sound field simulation and measurement.J Biomech Eng. 2002 Aug;124(4):450-5. doi: 10.1115/1.1488169. J Biomech Eng. 2002. PMID: 12188211
-
Characterization of vibration and acoustic noise in a gradient-coil insert.MAGMA. 2004 Sep;17(1):12-27. doi: 10.1007/s10334-004-0041-0. Epub 2004 Jun 23. MAGMA. 2004. PMID: 15221661
-
Acoustic noise in a small-format 3.0-T neonatal MRI system.Pediatr Radiol. 2024 Nov;54(12):2068-2076. doi: 10.1007/s00247-024-06070-9. Epub 2024 Oct 15. Pediatr Radiol. 2024. PMID: 39404888
-
Acoustic noise concerns in functional magnetic resonance imaging.Hum Brain Mapp. 2003 Nov;20(3):123-41. doi: 10.1002/hbm.10134. Hum Brain Mapp. 2003. PMID: 14601139 Free PMC article. Review.
-
Electromagnetic computation and modeling in MRI.Med Phys. 2017 Mar;44(3):1186-1203. doi: 10.1002/mp.12103. Med Phys. 2017. PMID: 28079264 Review.
Cited by
-
In situ active control of noise in a 4 T MRI scanner.J Magn Reson Imaging. 2011 Sep;34(3):662-9. doi: 10.1002/jmri.22694. Epub 2011 Jul 12. J Magn Reson Imaging. 2011. PMID: 21751284 Free PMC article.
-
Overview of Methods for Noise and Heat Reduction in MRI Gradient Coils.Front Phys. 2022 Jul;10:907619. doi: 10.3389/fphy.2022.907619. Epub 2022 Jul 8. Front Phys. 2022. PMID: 36506821 Free PMC article.
-
Theoretical, numerical, and experimental modal analysis of a single-winding gradient coil insert cylinder.MAGMA. 2006 Aug;19(3):152-66. doi: 10.1007/s10334-006-0038-y. Epub 2006 Aug 1. MAGMA. 2006. PMID: 16896886
-
CNS animal fMRI in pain and analgesia.Neurosci Biobehav Rev. 2011 Apr;35(5):1125-43. doi: 10.1016/j.neubiorev.2010.11.005. Epub 2010 Nov 30. Neurosci Biobehav Rev. 2011. PMID: 21126534 Free PMC article.
-
Gradient and shim technologies for ultra high field MRI.Neuroimage. 2018 Mar;168:59-70. doi: 10.1016/j.neuroimage.2016.11.033. Epub 2016 Nov 30. Neuroimage. 2018. PMID: 27915120 Free PMC article. Review.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical