Effect of curing method and curing time on the microhardness and wear of pit and fissure sealants
- PMID: 11755590
- DOI: 10.1016/s0109-5641(01)00030-6
Effect of curing method and curing time on the microhardness and wear of pit and fissure sealants
Abstract
Objective: To evaluate the effects of a light source, polymerization time and storage time on the microhardness and wear of pit and fissure sealants.
Methods: Five commercial pit and fissure sealants (Fissurit F [FF], Teethmate F1 [TF], Apollo Seal [AS], Concise [CC], and Ultraseal XT Plus [US]) were used. Specimens were cured with a conventional visible light curing unit (Curing Light XL 3000) for 10, 20, 30, 40s or with a plasma arc light curing unit (Apollo 95E) for 3, 6, 9, 12s. The specimens were kept dry in light-shielded bottles at 37 degrees C for 1 week, then half of them were thermocycled. The rest of them were stored in distilled water in light-shielded bottles for another 30 days, which were kept in an incubator at 37 degrees C, followed by thermocycling. Microhardness and wear of the specimens were measured.
Results: Similar degree of microhardness was achieved with the shorter curing time with the plasma arc light curing unit as with the conventional visible light-curing unit. With conventional visible light curing, the microhardness of the top surface was higher than that of the bottom surface (P<0.05). With plasma arc light curing, the microhardness of the top surface was higher than that of the bottom surface for AS and CC, but for FF, TF and US, the microhardness of the top surface was lower than that of the bottom surface, except in the 3-s curing of US. For FF, AS, CC and US, wear in the 6s curing with plasma arc light was similar to or less than that of the 30s curing with conventional visible light, but for TF, wear of the 9s curing with plasma arc light was similar to that of the 20s curing with conventional visible light. After storage in distilled water for 30 days followed by thermocycling, there was a tendency towards a decrease in microhardness and an increase in wear. There was a significant negative correlation between microhardness and wear (P<0.01).
Significance: The tested curing methods differed significantly in their curing capacity. This study suggested that a plasma arc light curing unit needs shorter curing time than a visible light curing unit to achieve similar mechanical properties of the pit and fissure sealants tested.
Similar articles
-
Effect of light curing methods on microleakage and microhardness of different resin sealants.J Dent Child (Chic). 2011 Jul;78(2):88-95. J Dent Child (Chic). 2011. PMID: 22041113
-
Microhardness of resin composites polymerized by plasma arc or conventional visible light curing.Oper Dent. 2002 Jan-Feb;27(1):30-7. Oper Dent. 2002. PMID: 11817467
-
Comparative evaluation of the microhardness of 4 dental sealants.Eur J Paediatr Dent. 2007 Dec;8(4):179-82. Eur J Paediatr Dent. 2007. PMID: 18163852
-
Influence of extended light exposure time on the degree of conversion and plasticization of materials used as pit and fissure sealants.J Investig Clin Dent. 2010 Nov;1(2):151-5. doi: 10.1111/j.2041-1626.2010.00015.x. J Investig Clin Dent. 2010. PMID: 25427273
-
Effect of new light curing units on microleakage and microhardness of resin sealants.Dent Mater J. 2016;35(3):517-22. doi: 10.4012/dmj.2015-357. Dent Mater J. 2016. PMID: 27252010
Cited by
-
Effects of aging on surface properties and adhesion of Streptococcus mutans on various fissure sealants.Clin Oral Investig. 2009 Dec;13(4):419-26. doi: 10.1007/s00784-009-0256-6. Epub 2009 Feb 21. Clin Oral Investig. 2009. PMID: 19234725
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous