Indoor environmental quality in six commercial office buildings in the midwest United States
- PMID: 11757903
- DOI: 10.1080/104732201753214170
Indoor environmental quality in six commercial office buildings in the midwest United States
Abstract
The aims of this study were to characterize physical, mechanical, and environmental factors influencing indoor environmental quality (IEQ) in commercial office buildings; document occupant perceptions and psychosocial attributes; and evaluate relationships among these parameters. Six large office buildings in metropolitan areas were selected in Iowa, Minnesota, and Nebraska. Comprehensive sampling was conducted over one week in each building, during all four seasons. This paper presents the study methods and selected results from the first round of sampling (November 1996 to April 1997). Air flow and recirculation rates were quite variable, with the proportion of outdoor air provided to occupants ranging from 10 to 79 CFM/person. Carbon dioxide, carbon monoxide, and temperature were within ranges anticipated for nonproblem buildings. Relative humidity was low, ranging from 11.7 to 24.0 percent. Indoor geometric mean concentrations of total volatile organic compounds (TVOCs) ranged from 73 to 235 microg/m3. The most prevalent compounds included xylene, toluene, 2-propanol, limonene, and heptane. Geometric mean formaldehyde concentrations ranged from 1.7 to 13.3 microg/m3, and mean acetaldehyde levels ranged from <3.0 to 7.5 microg/m3. Airborne concentrations of culturable bacteria and fungi were low, with no samples exceeding 150 CFU/m3. Total (direct count) bioaerosols were more variable, ranging from 5010 to 10,700 organisms/m3. Geometric mean endotoxin concentrations ranged from 0.5 to 3.0 EU/m3. Respirable particulates (PM10) were low (14 to 36 microg/m3). Noise levels ranged from 48 to 56 dBA, with mean light values ranging from 200 to 420 lux. Environmental parameters were significantly correlated with each other. The prevalence of upper respiratory symptoms (dry eyes, runny nose), central nervous system symptoms (headache, irritability), and musculoskeletal symptoms (pain/stiffness in shoulders/neck) were elevated compared to other studies using similar questionnaires. Importantly, psychosocial factors were significantly related to increased symptoms in females, while environmental factors were more closely correlated with symptoms in males. Endotoxin concentrations were associated with symptoms in both males and females. These data will help to identify and quantify the relative role of factors that contribute to sick building syndrome. The data collected in this study may also be used to evaluate the effectiveness of current building operation practices, and can be used to prioritize allocations of resources for reduction of risk associated with IEQ complaints.
Similar articles
-
Concentrations of airborne culturable bacteria in 100 large US office buildings from the BASE study.Indoor Air. 2005;15 Suppl 9:71-81. doi: 10.1111/j.1600-0668.2005.00346.x. Indoor Air. 2005. PMID: 15910532
-
Symptoms prevalence among office workers of a sealed versus a non-sealed building: associations to indoor air quality.Environ Int. 2009 Nov;35(8):1136-41. doi: 10.1016/j.envint.2009.07.005. Epub 2009 Aug 8. Environ Int. 2009. PMID: 19665795
-
[Air quality in schools - classroom levels of carbon dioxide (CO2), volatile organic compounds (VOC), aldehydes, endotoxins and cat allergen].Gesundheitswesen. 2008 Feb;70(2):88-97. doi: 10.1055/s-2008-1046775. Gesundheitswesen. 2008. PMID: 18348098 German.
-
Summary of human responses to ventilation.Indoor Air. 2004;14 Suppl 7:102-18. doi: 10.1111/j.1600-0668.2004.00279.x. Indoor Air. 2004. PMID: 15330778 Review.
-
Cabin air quality: an overview.Aviat Space Environ Med. 2002 Mar;73(3):211-5. Aviat Space Environ Med. 2002. PMID: 11908887 Review.
Cited by
-
Airborne environmental injuries and human health.Clin Rev Allergy Immunol. 2006 Aug;31(1):1-101. doi: 10.1385/CRIAI:31:1:1. Clin Rev Allergy Immunol. 2006. PMID: 16960302 Free PMC article. Review.
-
Review of bioaerosols in indoor environment with special reference to sampling, analysis and control mechanisms.Environ Int. 2015 Dec;85:254-72. doi: 10.1016/j.envint.2015.09.018. Epub 2015 Oct 3. Environ Int. 2015. PMID: 26436919 Free PMC article. Review.
-
Characterization of Indoor Air Quality on a College Campus: A Pilot Study.Int J Environ Res Public Health. 2019 Jul 30;16(15):2721. doi: 10.3390/ijerph16152721. Int J Environ Res Public Health. 2019. PMID: 31366132 Free PMC article.
-
Fighting COVID-19 with water.J Glob Health. 2020 Jun;10(1):010344. doi: 10.7189/jogh.10.010344. J Glob Health. 2020. PMID: 32373322 Free PMC article. No abstract available.
-
Gender, airborne chemical monitoring, and physical work environment are related to indoor air symptoms among nonindustrial workers in the Klang Valley, Malaysia.Ther Clin Risk Manag. 2013;9:87-105. doi: 10.2147/TCRM.S39136. Epub 2013 Mar 8. Ther Clin Risk Manag. 2013. PMID: 23526736 Free PMC article.