Early second-trimester low umbilical coiling index predicts small-for-gestational-age fetuses
- PMID: 11758023
- DOI: 10.7863/jum.2001.20.11.1183
Early second-trimester low umbilical coiling index predicts small-for-gestational-age fetuses
Abstract
Objective: To evaluate the role of the early second-trimester Doppler velocimetric studies of the umbilical coiling index and umbilical cord cross-sectional area as tests for the prediction of small-for-gestational age infants.
Methods: Doppler blood flow studies in 147 singleton pregnancies at risk for delivery of a small-for-gestational-age neonate were performed at 15 +/- 1 (SD) weeks' gestation from the uterine artery, umbilical artery, middle cerebral artery, inferior vena cava, and ductus venosus. Pulsatility index values were calculated for the arteries, and preload index values and systolic-atrial contraction ratios were calculated for the veins. The sonographic cross-sectional area of the umbilical cord was measured in a plane adjacent to the insertion into the fetal abdomen. The umbilical coiling index was calculated by using sonographic longitudinal views of cord vessels from several segments antenatally and by dividing the total number of helices by cord length (centimeters) postnatally. Small-for-gestational-age neonates were identified when the birth weight was below the 10th percentile for gestational age.
Results: Among 147 pregnancies studied, 124 fulfilled the study criteria. Thirty-nine of the neonates were small for gestational age at birth (31.5%). The mean +/- SD gestational age at delivery of the appropriate-for-gestational-age neonates was 39.7 +/- 1.28 weeks, and that of the small-for-gestational-age neonates was 36.4 +/- 2.9 weeks (range, 28-40 weeks). The best single predictor of a small-for-gestational-age infant was the coiling index, with sensitivity of 79%, specificity of 86%, a positive predictive value of 72%, and a negative predictive value of 90%.
Conclusions: The umbilical coiling index measured in the second trimester is useful in predicting the birth of a small-for-gestational-age infant and may serve as a marker for subsequent growth restriction.
Similar articles
-
Evaluation of midtrimester ductus venosus diameter and peak systolic velocity to predict late onset small for gestational age fetuses.J Matern Fetal Neonatal Med. 2022 Oct;35(20):3984-3990. doi: 10.1080/14767058.2020.1846175. Epub 2020 Nov 15. J Matern Fetal Neonatal Med. 2022. PMID: 33190543
-
Sonographic atypical vascular coiling of the umbilical cord.Prenat Diagn. 2005 Jan;25(1):1-6. doi: 10.1002/pd.1043. Prenat Diagn. 2005. PMID: 15662669
-
Ultrasound evaluation of abnormal umbilical cord coiling in second trimester of gestation in association with adverse pregnancy outcome.Am J Obstet Gynecol. 2005 Aug;193(2):387-94. doi: 10.1016/j.ajog.2004.12.092. Am J Obstet Gynecol. 2005. PMID: 16098860
-
Evidence-based national guidelines for the management of suspected fetal growth restriction: comparison, consensus, and controversy.Am J Obstet Gynecol. 2018 Feb;218(2S):S855-S868. doi: 10.1016/j.ajog.2017.12.004. Am J Obstet Gynecol. 2018. PMID: 29422214 Review.
-
Prenatal ultrasonographic morphologic assessment of the umbilical cord: a review. Part I.Obstet Gynecol Surv. 1997 Aug;52(8):506-14. doi: 10.1097/00006254-199708000-00022. Obstet Gynecol Surv. 1997. PMID: 9267868 Review.
Cited by
-
Gestational diabetes mellitus: the correlation between umbilical coiling index, and intrapartum as well as neonatal outcomes.J Diabetes Metab Disord. 2019 Apr 23;18(1):51-57. doi: 10.1007/s40200-019-00389-z. eCollection 2019 Jun. J Diabetes Metab Disord. 2019. PMID: 31275874 Free PMC article.
-
Antenatal Umbilical Coiling Index and Newborn Outcomes: Cohort Study.J Clin Imaging Sci. 2017 May 22;7:21. doi: 10.4103/jcis.JCIS_111_16. eCollection 2017. J Clin Imaging Sci. 2017. PMID: 28584688 Free PMC article.
-
Umbilical cord coiling: clinical outcomes in an unselected population and systematic review.Virchows Arch. 2014 Jan;464(1):105-12. doi: 10.1007/s00428-013-1513-2. Epub 2013 Nov 21. Virchows Arch. 2014. PMID: 24259031
-
Allometric metabolic scaling and fetal and placental weight.Placenta. 2009 Apr;30(4):355-60. doi: 10.1016/j.placenta.2009.01.006. Epub 2009 Mar 4. Placenta. 2009. PMID: 19264357 Free PMC article.
-
Umbilical cord characteristics and their association with adverse pregnancy outcomes: A systematic review and meta-analysis.PLoS One. 2020 Sep 24;15(9):e0239630. doi: 10.1371/journal.pone.0239630. eCollection 2020. PLoS One. 2020. PMID: 32970750 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical