Feasibility of a left atrial electrical disconnection procedure for atrial fibrillation using transcatheter radiofrequency ablation
- PMID: 11761416
- DOI: 10.1046/j.1540-8167.2001.01278.x
Feasibility of a left atrial electrical disconnection procedure for atrial fibrillation using transcatheter radiofrequency ablation
Abstract
Introduction: An effective, catheter-based treatment for persistent atrial fibrillation (AF) remains elusive. This study assessed the feasibility of transcatheter left atrial (LA) electrical disconnection and its effect on AF inducibility.
Method and results: Thirteen anesthetized swine underwent noncontact mapping of the right atrium (RA) during coronary sinus (CS) pacing. Sites of earliest RA activation were identified using isopotential maps. An ablation catheter was navigated to these sites and a cluster of radiofrequency (RF) lesions applied until earliest activation shifted to a new site. The procedure was repeated until the atria were electrically disconnected. AF induction was attempted before and after ablation. Earliest RA activation was the CS os during proximal CS pacing and Bachmann's bundle during distal CS pacing. These two sites were successfully ablated in all 13 animals. Earliest activation then shifted to the fossa ovalis. RF energy was applied at a median of 2.5 sites (range 1 to 5) around the fossa, then at sites in the triangle of Koch, septum, cavotricuspid isthmus, and posterior wall. Atrial electrical disconnection was achieved in 10 of 13 animals (5 LA electrical disconnection, 3 RA electrical disconnection, 2 biatrial electrical disconnection with complete heart block). After atrial electrical disconnection, the LA became electrically silent. Before ablation, AF was inducible in every animal. After atrial electrical disconnection, AF was inducible in 3 of 10 animals.
Conclusion: Atrial electrical disconnection is feasible using noncontact mapping and RF ablation. Successful electrical disconnection of the atria reduces AF inducibility. This approach is worthy of further evaluation as a management strategy for persistent AF, combined with device therapies.
Comment in
-
When technology exceeds knowledge, is success a reasonable expectation?J Cardiovasc Electrophysiol. 2001 Nov;12(11):1284-5. doi: 10.1046/j.1540-8167.2001.01284.x. J Cardiovasc Electrophysiol. 2001. PMID: 11761417 No abstract available.
Similar articles
-
Characteristics of right atrial activation during coronary sinus pacing.J Cardiovasc Electrophysiol. 2002 Aug;13(8):794-800. doi: 10.1046/j.1540-8167.2002.00794.x. J Cardiovasc Electrophysiol. 2002. PMID: 12212700
-
Human study of biatrial electrical coupling: determinants of endocardial septal activation and conduction over interatrial connections.Circulation. 2004 Oct 12;110(15):2083-9. doi: 10.1161/01.CIR.0000144461.83835.A1. Epub 2004 Oct 4. Circulation. 2004. PMID: 15466628
-
Electrical disconnection of the coronary sinus by radiofrequency catheter ablation to isolate a trigger of atrial fibrillation.J Cardiovasc Electrophysiol. 2004 Mar;15(3):364-8. doi: 10.1046/j.1540-8167.2004.03300.x. J Cardiovasc Electrophysiol. 2004. PMID: 15030429
-
Hybrid therapy of atrial fibrillation.Ital Heart J. 2002 Oct;3(10):571-8. Ital Heart J. 2002. PMID: 12478814 Review.
-
Bi-atrial mapping of atrial arrhythmias.Card Electrophysiol Rev. 2002 Dec;6(4):378-82. doi: 10.1023/a:1021176123007. Card Electrophysiol Rev. 2002. PMID: 12438816 Review.
Cited by
-
Dynamic alterations in right atrial activation during atrial fibrillation.J Interv Card Electrophysiol. 2003 Feb;8(1):37-40. doi: 10.1023/a:1022383713346. J Interv Card Electrophysiol. 2003. PMID: 12652175
-
Analysis of drug-induced and spontaneous cardioversions reveals similar patterns leading to termination of atrial fibrillation.Front Physiol. 2024 Jul 18;15:1399037. doi: 10.3389/fphys.2024.1399037. eCollection 2024. Front Physiol. 2024. PMID: 39092426 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical