Acute ventricular reduction with the acorn cardiac support device: effect on progressive left ventricular dysfunction and dilation in dogs with chronic heart failure
Abstract
Background and aim: Surgical resection of myocardium that acutely reduces left ventricular (LV) volume in patients with advanced heart failure (HF), the so-called "Batista Operation," remains controversial. We examined the effects of acute LV reduction with the Acorn Cardiac Support Device (CSD) in dogs with HF (LV ejection fraction < 30%).
Methods: HF was produced in 15 dogs by intracoronary microembolization. In nine dogs, intravenous dobutamine was administered to reduce LV end-diastolic dimension (LVEDD) by 10%-25%. While on dobutamine infusion, the CSD, a preformed knitted polyester device, was surgically placed around the ventricles, anchored to the arteriovenous (AV) groove, and tailored anteriorly to fit snugly over the ventricles. Dogs were then weaned off dobutamine.
Results: On average, the procedure reduced LVEDD by 7 +/- 1 mm (range 5-12 mm). Of the nine dogs, two died before completion of the study and seven survived for the entire period. Six dogs did not undergo device placement and served as controls. All were followed for 3 months prior to sacrifice. In controls, LV end-diastolic volume increased after 3 months (66 +/- 5 mL vs 77 +/- 6 mL; p = 0.007), while in CSD-treated dogs (n = 7), it decreased (80 +/- 5 mL vs 60 +/- 3 mL; p = 0.002). In controls, LV ejection fraction (EF) decreased after 3 months (27 +/- 1% vs 23 +/- 1%; p = 0.001) but was unchanged in CSD-treated dogs (25 +/- 1% vs 26 +/- 1%; p = 0.66). Compared to controls, CSD-treated dogs showed improved LV diastolic dysfunction and chamber sphericity, decreased wall stress, and no functional mitral regurgitation (MR).
Conclusion: In dogs with advanced HF, acute LV reduction with the Acorn CSD prevents progressive global LV dilatation and ameliorates functional MR.
Similar articles
-
Global left ventricular remodeling with the Acorn Cardiac Support Device: hemodynamic and angiographic findings in dogs with heart failure.Heart Fail Rev. 2005 Jun;10(2):109-15. doi: 10.1007/s10741-005-4638-9. Heart Fail Rev. 2005. PMID: 16258718 Review.
-
Passive epicardial containment prevents ventricular remodeling in heart failure.Ann Thorac Surg. 2000 Oct;70(4):1275-80. doi: 10.1016/s0003-4975(00)01755-0. Ann Thorac Surg. 2000. PMID: 11081885
-
Left ventricular histomorphometric findings in dogs with heart failure treated with the Acorn Cardiac Support Device.Heart Fail Rev. 2005 Jun;10(2):141-7. doi: 10.1007/s10741-005-4641-1. Heart Fail Rev. 2005. PMID: 16258721 Review.
-
Sustained benefits of the CorCap Cardiac Support Device on left ventricular remodeling: three year follow-up results from the Acorn clinical trial.Ann Thorac Surg. 2007 Oct;84(4):1236-42. doi: 10.1016/j.athoracsur.2007.03.096. Ann Thorac Surg. 2007. PMID: 17888975 Clinical Trial.
-
Reversal of chronic molecular and cellular abnormalities due to heart failure by passive mechanical ventricular containment.Circ Res. 2003 Nov 28;93(11):1095-101. doi: 10.1161/01.RES.0000101932.70443.FE. Epub 2003 Oct 16. Circ Res. 2003. PMID: 14563716
Cited by
-
Electrical modalities beyond pacing for the treatment of heart failure.Heart Fail Rev. 2011 May;16(3):315-25. doi: 10.1007/s10741-010-9206-2. Heart Fail Rev. 2011. PMID: 21104313 Free PMC article. Review.
-
Mechanical approaches to alter remodeling.Curr Heart Fail Rep. 2004 Apr-May;1(1):14-8. doi: 10.1007/s11897-004-0012-9. Curr Heart Fail Rep. 2004. PMID: 16036020 Review.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous