Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2001 Dec;71(6):461-5.
doi: 10.1043/0003-3219(2001)071<0461:EONCSA>2.0.CO;2.

Evaluation of nonrinse conditioning solution and a compomer as an alternative method of bonding orthodontic bracket

Affiliations
Comparative Study

Evaluation of nonrinse conditioning solution and a compomer as an alternative method of bonding orthodontic bracket

S E Bishara et al. Angle Orthod. 2001 Dec.

Abstract

Damage to the enamel surface during bonding and debonding of orthodontic brackets is a clinical concern. Alternative bonding methods that minimize enamel surface damage while maintaining a clinically useful bond strength are an aim of current research. The purpose of this study was to compare the effects of using two enamel conditioners and adhesives on the shear bond strength and bracket failure location. Forty freshly extracted human molars were pumiced and randomly divided into two groups of 20 teeth. Metal orthodontic brackets were bonded to the enamel surface by one of two protocols: 37% phosphoric acid with a composite adhesive (Transbond XT) or a nonrinse conditioner with a compomer adhesive (Dyract flow). The teeth were mounted in phenolic rings and stored in deionized water at 37 degrees C for 24 hours. A Zwick Universal Testing Machine was used to determine shear bond strengths in MegaPascals. The residual adhesive on the enamel surface was evaluated using the Adhesive Remnant Index. Student t-test and chi2-test were used to compare the two groups. Significance was predetermined at P < or = .05. The results of the t-tests indicated that there were significant differences between the two adhesive systems (t = 11.18 and P = .001) with the nonrinse conditioner/compomer system having lower shear bond strength (X = 1.7 +/- 0.9 MPa) than the phosphoric acid/composite adhesive (X = 10.4 +/- 2.8 MPa). The results of the Chi Square test evaluating the residual adhesives on the enamel surfaces also revealed significant differences between the two groups (chi2 = 7.62, P = .022). In conclusion, a nonrinse conditioner used with a compomer adhesive had significantly lower shear bond strength than a phosphoric acid/composite adhesive system.

PubMed Disclaimer

Publication types