Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2002 Jan;94(1):163-8, table of contents.
doi: 10.1097/00000539-200201000-00031.

Remifentanil provides hemodynamic stability and faster awakening time in transsphenoidal surgery

Affiliations
Clinical Trial

Remifentanil provides hemodynamic stability and faster awakening time in transsphenoidal surgery

Marco Gemma et al. Anesth Analg. 2002 Jan.

Abstract

In this prospective study, we evaluated the effects of remifentanil in ASA I-II patients undergoing transsphenoidal surgery. After the induction of anesthesia, patients were randomly allocated to the Isoflurane (n = 22, 60% nitrous oxide, isoflurane up to 2% end-tidal) or Remifentanil group (n = 21, 60% nitrous oxide, 0.5% end-tidal isoflurane, remifentanil up to 2 microg x kg(-1) x min(-1)). If mean arterial pressure (MAP) increased >80 mm Hg during maximal dosage of isoflurane or remifentanil, labetalol was administered. At the end of anesthesia, extubation and awakening times, respiratory rate, SpO(2), MAP, heart rate, and adverse effects were recorded. Hemodynamics and bleeding (minimal, mild, moderate, severe) were not different between groups. Bleeding grade increased with MAP >80 mm Hg (P < 0.001). Labetalol was administered to 20 patients in the Isoflurane group, and 10 patients in the Remifentanil group (P < 0.01). The dose of labetalol was larger in the Isoflurane group (1.0 +/- 0.6 versus 0.5 +/- 0.7 mg/kg, P < 0.05). Time to extubation did not differ, whereas time to follow commands was shorter in Remifentanil patients (16 +/- 8 versus 10 +/- 2 min, P < 0.01). No adverse effects occurred in the early postoperative period.

Implications: In patients undergoing transsphenoidal surgery, balanced anesthesia with remifentanil (0.22 +/- 0.17 microg x kg(-1) x min(-1)) provides faster awakening time, as compared with large-dose volatile-based anesthesia, without the risk of postoperative opioid respiratory depression.

PubMed Disclaimer

Publication types

LinkOut - more resources