BIA-MS-MS: biomolecular interaction analysis for functional proteomics
- PMID: 11780967
- DOI: 10.1016/S0167-7799(01)01797-8
BIA-MS-MS: biomolecular interaction analysis for functional proteomics
Abstract
One of the experimental processes of functional proteomics is the analysis of protein interaction. Here, we review a new analytical platform, BIA-MS, for protein interaction analysis. BIA-MS is an integration of a surface plasmon resonance biosensor for real-time interaction analysis and mass spectrometry for the subsequent identification of interacting molecules.
Similar articles
-
Advances in surface plasmon resonance biomolecular interaction analysis mass spectrometry (BIA/MS).J Mol Recognit. 1999 Mar-Apr;12(2):77-93. doi: 10.1002/(SICI)1099-1352(199903/04)12:2<77::AID-JMR448>3.0.CO;2-G. J Mol Recognit. 1999. PMID: 10398399 Review.
-
Practical considerations in BIA/MS: optimizing the biosensor-mass spectrometry interface.J Mol Recognit. 2000 May-Jun;13(3):140-5. doi: 10.1002/1099-1352(200005/06)13:3<140::AID-JMR496>3.0.CO;2-P. J Mol Recognit. 2000. PMID: 10867709 Review.
-
Surface plasmon resonance mass spectrometry for protein analysis.Methods Mol Biol. 2006;328:131-9. doi: 10.1385/1-59745-026-X:131. Methods Mol Biol. 2006. PMID: 16785645
-
BIA/MS: interfacing biomolecular interaction analysis with mass spectrometry.Anal Biochem. 1997 Jan 1;244(1):124-32. doi: 10.1006/abio.1996.9871. Anal Biochem. 1997. PMID: 9025918
-
Biosensor chip mass spectrometry: a chip-based proteomics approach.Electrophoresis. 2000 Apr;21(6):1155-63. doi: 10.1002/(SICI)1522-2683(20000401)21:6<1155::AID-ELPS1155>3.0.CO;2-X. Electrophoresis. 2000. PMID: 10786888 Review.
Cited by
-
Peptide arrays with designed alpha-helical structures for characterization of proteins from FRET fingerprint patterns.Mol Divers. 2004;8(3):209-18. doi: 10.1023/b:modi.0000036237.82584.2d. Mol Divers. 2004. PMID: 15384414
-
Extracellular Vesicles Produced by Bifidobacterium longum Export Mucin-Binding Proteins.Appl Environ Microbiol. 2020 Sep 17;86(19):e01464-20. doi: 10.1128/AEM.01464-20. Print 2020 Sep 17. Appl Environ Microbiol. 2020. PMID: 32737132 Free PMC article.
-
Quantitative evaluation of sensitivity and selectivity of multiplex nanoSPR biosensor assays.Biophys J. 2007 Nov 15;93(10):3684-92. doi: 10.1529/biophysj.107.110064. Epub 2007 Jul 27. Biophys J. 2007. PMID: 17660314 Free PMC article.
-
Using solution-phase nanoparticles, surface-confined nanoparticle arrays and single nanoparticles as biological sensing platforms.J Fluoresc. 2004 Jul;14(4):355-67. doi: 10.1023/b:jofl.0000031817.35049.1f. J Fluoresc. 2004. PMID: 15617378 Review.
-
Combined Analysis Based on a Crystalline Sponge Method.Anal Sci. 2021 Jan 10;37(1):167-175. doi: 10.2116/analsci.20SAR07. Epub 2020 Oct 30. Anal Sci. 2021. PMID: 33132236 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources