The emmetropic and the iseikonic implant lens: computer calculation of the refractive power and its accuracy
- PMID: 1178154
- DOI: 10.1159/000307571
The emmetropic and the iseikonic implant lens: computer calculation of the refractive power and its accuracy
Abstract
The preoperative calculation of the power of a lens prosthesis and the resulting aniseikonia is given, as well as diagrams for reading the emmetropizing and the iseikonizing power of the lens. The consequences of an inaccuracy in the measurement of the dimensional and refractive properties of the eyes are calculated. It can be concluded that the main determinant for an accurate prediction of the power of the intraocular lens prosthesis is the axial length measurement. Since this measurement is carried out by means of ultrasound biometry, it is necessary to emphasize the adequate application of this technique. The problem as to whether an emmetropizing, or an iseikonizing lens should be implanted may be solved with the data supplied by the computer program. A flow chart for this program is given in an appendix.
Similar articles
-
The optical design of intraocular lens implants.Ophthalmic Surg. 1975 Fall;6(3):17-31. Ophthalmic Surg. 1975. PMID: 1187085
-
Immersion B-guided versus contact A-mode biometry for accurate measurement of axial length and intraocular lens power calculation in siliconized eyes.Retina. 2011 Feb;31(2):262-5. doi: 10.1097/IAE.0b013e3181e17f39. Retina. 2011. PMID: 20829737
-
The correlation of corneal refractive power, axial length, and the refractive power of the emmetropizing intraocular lens in cataractous eyes.Ger J Ophthalmol. 1996 Nov;5(6):328-31. Ger J Ophthalmol. 1996. PMID: 9479513
-
Preoperative cataract evaluation: intraocular lens power calculation.Int Ophthalmol Clin. 1982 Summer;22(2):37-75. doi: 10.1097/00004397-198202220-00005. Int Ophthalmol Clin. 1982. PMID: 7045010 Review. No abstract available.
-
Calculation of intraocular lens power: a review.Acta Ophthalmol Scand. 2007 Aug;85(5):472-85. doi: 10.1111/j.1600-0420.2007.00879.x. Epub 2007 Apr 2. Acta Ophthalmol Scand. 2007. PMID: 17403024 Review.
Cited by
-
Focused ultrasound in ophthalmology.Clin Ophthalmol. 2016 Sep 27;10:1865-1875. doi: 10.2147/OPTH.S99535. eCollection 2016. Clin Ophthalmol. 2016. PMID: 27757007 Free PMC article. Review.
-
Factors influencing the accuracy of the SRK formula in the intraocular less power calculation.Doc Ophthalmol. 1994;85(3):223-42. doi: 10.1007/BF01664930. Doc Ophthalmol. 1994. PMID: 7924850
-
Hereditary retinitis pigmentosa: recent findings from electroretinography, fundus reflectometry, and psychophysics.Int Ophthalmol Clin. 1980 Spring;20(1):39-52. doi: 10.1007/BF00149254. Int Ophthalmol Clin. 1980. PMID: 6995379 Review. No abstract available.
-
Evaluation of ultrasound velocity in enucleated equine aqueous humor, lens and vitreous body.BMC Vet Res. 2014 Oct 14;10:250. doi: 10.1186/s12917-014-0250-3. BMC Vet Res. 2014. PMID: 25312851 Free PMC article.
-
An ensemble-based approach for estimating personalized intraocular lens power.Sci Rep. 2021 Nov 25;11(1):22961. doi: 10.1038/s41598-021-02288-x. Sci Rep. 2021. PMID: 34824338 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources