Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2001 Nov-Dec;21(6):546-53.

Acidosis correction with a new 25 mmol/l bicarbonate/15 mmol/l lactate peritoneal dialysis solution

Affiliations
  • PMID: 11783762
Clinical Trial

Acidosis correction with a new 25 mmol/l bicarbonate/15 mmol/l lactate peritoneal dialysis solution

A M Carrasco et al. Perit Dial Int. 2001 Nov-Dec.

Abstract

Objective: The aim of this study was to evaluate the effects of a combined 25 mmol/L bicarbonate/15 mmol/L lactate-based solution (Bic/Lac), compared to a 35 mmol/L lactate solution (Lac)--the most commonly used solution for patients in southern Europe--on the venous plasma bicarbonate level in patients treated with continuous ambulatory peritoneal dialysis (CAPD).

Design: This was a randomized, parallel, controlled, open-label study, with patients studied for a period of 3 months preceded by a 1-month baseline and followed by a 1-month follow-up. Patients used the 35 mmol/L lactate solution during baseline and follow-up periods.

Setting: Four Spanish nephrology centers.

Patients: Thirty-one (20 Bic/Lac, 11 Lac) well-dialyzed (creatinine clearance > 55 L/week/1.73 m2 body surface area) CAPD patients.

Interventions: Blood samples were taken for biochemistry tests at all visits. A physical examination was completed at baseline and month 3, and a medical update was completed after 1, 2, and 3 months, and at the follow-up visit. Adverse-event monitoring and notation of prescription changes were carried out continuously.

Main outcome measure: Effect on venous plasma bicarbonate level.

Results: Venous plasma bicarbonate rose by 3.1 mmol/L (confidence intervals 1.6-4.8),from a baseline level of 23.0 mmol/L during the treatment period in those patients treated with Bic/Lac (p < 0.05 vs Lac). The number of acidotic patients (venous plasma bicarbonate < 24 mmol/L) was statistically significantly reduced at every treatment period visit in the Bic/Lac group (p < 0.05). There were no adverse findings with respect to vital signs, physical examination, or clinical symptoms, apart from one death in the control group.

Conclusions: The new Bic/Lac solution allowed better correction of acid-base status than the lactate solution.