Anatomical outcomes of surgery for idiopathic macular hole as determined by optical coherence tomography
- PMID: 11786054
- DOI: 10.1001/archopht.120.1.29
Anatomical outcomes of surgery for idiopathic macular hole as determined by optical coherence tomography
Abstract
Objectives: To determine the rate of anatomical closure of idiopathic macular holes undergoing vitreous surgery with respect to preoperative horizontal diameter as determined by optical coherence tomography (OCT) and to correlate postoperative visual acuity, duration of symptoms, and late reopening with initial idiopathic macular hole diameter by OCT.
Materials and methods: Forty eyes of 40 patients with an idiopathic macular hole were examined with OCT before and after vitreous surgery. All eyes were treated with pars plana vitrectomy, peeling of posterior cortical vitreous, and dilute perfluoropropane or sulfur hexafluoride gas. Face-down positioning was maintained for 7 to 14 days.
Results: Twenty-two (92%) of 24 eyes with a preoperative idiopathic macular hole diameter smaller than 400 microm measured by OCT attained anatomical closure following surgery. Anatomical closure was observed in 9 (56%) of 16 eyes with a macular hole diameter of 400 microm or larger measured by OCT (P =.02). The median postoperative visual acuity improvement was 4 Snellen lines in the 31 eyes achieving anatomical closure and no change in the 9 eyes not achieving anatomical closure (P< .001). Late macular hole reopening at longer than 6 months occurred in 3 (10%) of 31 eyes with an initially closed macular hole. This event was observed only in macular holes 400 microm or larger measured by OCT. The preoperative macular hole diameter (P =.02) and duration of symptoms (P =.02) were factors predictive of anatomical closure of the macular hole postoperatively.
Conclusions: The postoperative closure of idiopathic macular holes following vitreous surgery was related to the preoperative macular hole diameter determined by OCT, with lesions smaller than 400 microm demonstrating higher success rates. A trend toward greater visual acuity improvement was demonstrated for idiopathic macular holes smaller than 400 microm. Late reopening was only seen in macular holes that were 400 microm or larger measured by OCT. Preoperative analysis and measurement of idiopathic macular holes with OCT may help delineate postoperative expectations for successful anatomical closure of the macular hole, visual acuity, and long-term closure.
Similar articles
-
Macular hole surgery with and without internal limiting membrane peeling.Ophthalmology. 2000 Oct;107(10):1939-48; discussion 1948-9. doi: 10.1016/s0161-6420(00)00331-6. Ophthalmology. 2000. PMID: 11013203
-
Anterior chamber aqueous flare is not a predictor for surgical closure of full-thickness idiopathic macular holes.Eur J Ophthalmol. 2020 Sep;30(5):1127-1134. doi: 10.1177/1120672119843283. Epub 2019 Apr 10. Eur J Ophthalmol. 2020. PMID: 30968716
-
Retrospective study of changes in ocular coherence tomography characteristics after failed macular hole surgery and outcomes of fluid-gas exchange for persistent macular hole.Indian J Ophthalmol. 2018 Aug;66(8):1130-1135. doi: 10.4103/ijo.IJO_1119_17. Indian J Ophthalmol. 2018. PMID: 30038157 Free PMC article.
-
Macular holes: vitreoretinal relationships and surgical approaches.Eye (Lond). 2008 Oct;22(10):1301-9. doi: 10.1038/eye.2008.23. Epub 2008 Mar 7. Eye (Lond). 2008. PMID: 18327161 Review.
-
Pediatric idiopathic macular hole - A case report and review of literature.Indian J Ophthalmol. 2020 Jan;68(1):241-244. doi: 10.4103/ijo.IJO_354_19. Indian J Ophthalmol. 2020. PMID: 31856539 Free PMC article. Review.
Cited by
-
Indistinct retinal outer layers in the walls of the idiopathic full-thickness macular hole - A potential predictive biomarker for surgical outcomes.Indian J Ophthalmol. 2022 Dec;70(12):4383-4389. doi: 10.4103/ijo.IJO_1215_22. Indian J Ophthalmol. 2022. PMID: 36453349 Free PMC article.
-
Clinical Observation of Anatomical and Visual Outcomes of Macular Hole after Inverted Internal Limiting Membrane Flap in Patients with Idiopathic Macular.J Healthc Eng. 2023 Feb 15;2023:5816473. doi: 10.1155/2023/5816473. eCollection 2023. J Healthc Eng. 2023. PMID: 36844949 Free PMC article.
-
Development and validation of a deep learning system to classify aetiology and predict anatomical outcomes of macular hole.Br J Ophthalmol. 2023 Jan;107(1):109-115. doi: 10.1136/bjophthalmol-2021-318844. Epub 2021 Aug 4. Br J Ophthalmol. 2023. PMID: 34348922 Free PMC article.
-
Enhanced vitreous imaging optical coherence tomography in primary macular holes.Int Ophthalmol. 2016 Jun;36(3):355-63. doi: 10.1007/s10792-015-0126-y. Epub 2015 Sep 8. Int Ophthalmol. 2016. PMID: 26349565
-
Optical coherence tomography: A guide to interpretation of common macular diseases.Indian J Ophthalmol. 2018 Jan;66(1):20-35. doi: 10.4103/ijo.IJO_902_17. Indian J Ophthalmol. 2018. PMID: 29283118 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous