Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2002 Jan;61(1):256-65.
doi: 10.1046/j.1523-1755.2002.00098.x.

Identical decline of residual renal function in high-flux biocompatible hemodialysis and CAPD

Affiliations
Free article
Clinical Trial

Identical decline of residual renal function in high-flux biocompatible hemodialysis and CAPD

Will McKane et al. Kidney Int. 2002 Jan.
Free article

Abstract

Background: Patients on conventional hemodialysis lose residual renal function more rapidly than patients on continuous ambulatory peritoneal dialysis (CAPD). The effect of dialysis using synthetic membranes and ultrapure water is less clear.

Methods: The decline of urea clearance was compared in a cohort of 475 incident end-stage renal failure patients who received treatment with CAPD (N=175) or hemodialysis (HD) utilizing high-flux polysulphone membranes, ultrapure water, and bicarbonate as the buffer (N=300).

Results: CAPD patients were significantly younger, fitter (lower comorbidity severity score), less dependent (higher Karnofsky performance score) and less likely to have presented late than HD patients. There was no difference in the mean urea clearance in each group at dialysis initiation, or at any 6-month time point during the ensuing 48 months. This was true even after exclusion of patients who had died in the first year after initiation, those transferred to another dialysis modality, or those who had been transplanted. Only age and chronic interstitial disease predicted retention of urea clearance at one year. The rate of decline of urea clearance was similar in pre- and post-dialysis initiation phases, though there may have been a step-decline of about 2 mL/min at initiation, which requires further investigation.

Conclusions: In hemodialysis using high-flux biocompatible membranes and ultrapure water, residual renal function declines at a rate indistinguishable from that in CAPD. This may have important implications, since preservation of residual renal function has major benefits and is a valid therapeutic goal.

PubMed Disclaimer