Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2001 Nov;29(6):465-81.
doi: 10.1081/bio-100108551.

The effects of hemodilution with Hemolink upon hemodynamics and blood flow distribution in anesthetized dogs

Affiliations

The effects of hemodilution with Hemolink upon hemodynamics and blood flow distribution in anesthetized dogs

J G Kingma Jr et al. Artif Cells Blood Substit Immobil Biotechnol. 2001 Nov.

Corrected and republished in

Abstract

Hemoglobin based oxygen-carrying solutions (HBOCs) as hemoglobin replacement therapeutics are being tested for clinical use. Some of these products are associated with elevations in both systemic and pulmonary vascular resistances but their effect on the distribution of blood flow to major organs in larger animals have not been extensively described. We tested two formulations of o-raffinose cross-linked human hemoglobin, Hemolink (frozen Hemolink-1 and refrigerated Hemolink-2) and compared them to Pentaspan, a colloid volume expander in extensive clinical use. Cardiovascular measurements and the distribution of blood flow (radionuclide-labeled microspheres) to the major organs were determined in Beagle dogs (n=5 per group). After baseline measurements, either Hemolink-1, or Hemolink-2, or Pentaspan was exchange transfused in an isovolemic manner (resulting in hematocrit reduction to approximately 20-25%); measurements were made 30, 60, 120 and 180 min post-exchange. There was no significant difference in cardiac output, mean arterial pressures and systemic or pulmonary vascular resistance after exchange in any of the three groups. Myocardial blood flow increased in all three groups post-exchange but the increase was more sustained in the Hemolink groups. Endocardial/epicardial flow ratios were also maintained after exchange in all groups. Thus, Hemolink is ideally suited for volume replacement when used in conjunction with acute normovolemic hemodilution because under these circumstances, the adverse hemodynamic effects are alleviated while extra hemoglobin is added to the blood.

PubMed Disclaimer

LinkOut - more resources