Choosing new adsorbents for endogenous ultrapure infusion fluid: performances, safety and flow distribution
- PMID: 11797846
Choosing new adsorbents for endogenous ultrapure infusion fluid: performances, safety and flow distribution
Abstract
Adsorption may notably contribute to the removal of uremic toxins and to the efficiency of hemodialysis. We examined different uncoated stationary matrixes, charcoals and synthetic resins to establish their adsorptive capacities in relation to low (urea, creatinine) and high molecular weight (beta2-microglobulin, myoglobin) compounds in in vitro conditions (steady state and flow-through) using isotonic solutions or uremic ultrafiltrate. Trace metal, particle release analyses and scanning electron microscopy of different adsorbents were performed. Dynamic flow-distribution studies were made using 99Technetium and analysing the different regions of interest by single head gamma-camera. We show that adsorbents may differ greatly as to their adsorptive capacity depending on flow rate, nature, and total mass of the compounds to be removed from the ultrafiltrate. These studies suggest a methodological approach for screening stationary matrixes for possible application in hemodialysis.
Similar articles
-
In vivo removal of high- and low-molecular-weight compounds in hemodiafiltration with on-line regeneration of ultrafiltrate.Nephron Clin Pract. 2006;104(1):c55-60. doi: 10.1159/000093671. Epub 2006 May 30. Nephron Clin Pract. 2006. PMID: 16741371
-
[Middle molecules removal. Beyond beta2-microglobulin].Nefrologia. 2006;26(4):469-75. Nefrologia. 2006. PMID: 17058859 Spanish.
-
Adsorption in hemodialysis.Kidney Int Suppl. 2000 Aug;76:S60-5. doi: 10.1046/j.1523-1755.2000.07607.x. Kidney Int Suppl. 2000. PMID: 10936800 Review.
-
Clinical comparison of super high-flux HD and on-line HDF.Blood Purif. 2013;35 Suppl 1:81-4. doi: 10.1159/000346363. Epub 2013 Feb 25. Blood Purif. 2013. PMID: 23466386
-
Role of dialysis technology in the removal of uremic toxins.Hemodial Int. 2011 Oct;15 Suppl 1:S49-53. doi: 10.1111/j.1542-4758.2011.00602.x. Hemodial Int. 2011. PMID: 22093601 Review.
Cited by
-
Evidence that p-cresol and IL-6 are adsorbed by the HFR cartridge: towards a new strategy to decrease systemic inflammation in dialyzed patients?PLoS One. 2014 Apr 22;9(4):e95811. doi: 10.1371/journal.pone.0095811. eCollection 2014. PLoS One. 2014. PMID: 24755610 Free PMC article.
-
Proteomic analisys of protein extraction during hemofiltration with on-line endogenous reinfusion (HFR) using different polysulphone membranes.J Mater Sci Mater Med. 2014 Dec;25(12):2691-8. doi: 10.1007/s10856-014-5290-5. Epub 2014 Jul 30. J Mater Sci Mater Med. 2014. PMID: 25074835 Clinical Trial.
-
Vitamins (A, C and E) and oxidative status of hemodialysis patients treated with HFR and HFR-Supra.BMC Nephrol. 2016 Aug 26;17(1):120. doi: 10.1186/s12882-016-0315-6. BMC Nephrol. 2016. PMID: 27566671 Free PMC article. Clinical Trial.
-
Efficacy of Supra-HFR in Removing FGF23 and Cytokines: A Single Session Analysis.In Vivo. 2022 Jul-Aug;36(4):1769-1776. doi: 10.21873/invivo.12890. In Vivo. 2022. PMID: 35738602 Free PMC article.
-
A novel option for reducing free light chains in myeloma kidney: supra-hemodiafiltration with endogenous reinfusion (HFR).J Nephrol. 2015 Apr;28(2):251-4. doi: 10.1007/s40620-014-0130-8. Epub 2014 Aug 23. J Nephrol. 2015. PMID: 25149172
MeSH terms
Substances
LinkOut - more resources
Medical