IOP measurement and central corneal thickness
- PMID: 11801523
- PMCID: PMC1770959
- DOI: 10.1136/bjo.86.1.120
IOP measurement and central corneal thickness
Figures


Comment on
-
Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings.Br J Ophthalmol. 2001 Jan;85(1):85-7. doi: 10.1136/bjo.85.1.85. Br J Ophthalmol. 2001. PMID: 11133718 Free PMC article.
Similar articles
-
[How does central cornea thickness influence intraocular pressure during applanation and contour tonometry?].Klin Monbl Augenheilkd. 2012 Sep;229(9):917-27. doi: 10.1055/s-0031-1299536. Epub 2012 Sep 12. Klin Monbl Augenheilkd. 2012. PMID: 22972357 German.
-
The impact of central corneal thickness on intraocular pressure measured by non-contact tonometry.J Med Assoc Thai. 2011 May;94(5):574-8. J Med Assoc Thai. 2011. PMID: 21675447
-
[What to do if the intraocular pressure measurement does not appear reliable].J Fr Ophtalmol. 2010 Apr;33(4):279-84. doi: 10.1016/j.jfo.2010.02.007. Epub 2010 Mar 29. J Fr Ophtalmol. 2010. PMID: 20347507 Review. French.
-
Effect of corneal thickness on intraocular pressure measurements with the Pascal dynamic contour, Canon TX-10 non-contact and Goldmann applanation tonometers in healthy subjects.Clin Exp Optom. 2009 Jan;92(1):14-8. doi: 10.1111/j.1444-0938.2008.00299.x. Epub 2008 Jul 10. Clin Exp Optom. 2009. PMID: 18637107 Clinical Trial.
-
What biomechanical properties of the cornea are relevant for the clinician?Surv Ophthalmol. 2007 Nov;52 Suppl 2:S109-14. doi: 10.1016/j.survophthal.2007.08.004. Surv Ophthalmol. 2007. PMID: 17998034 Review.
Cited by
-
Central and paracentral corneal pachymetry in patients with normal tension glaucoma and ocular hypertension.Graefes Arch Clin Exp Ophthalmol. 2006 Feb;244(2):177-82. doi: 10.1007/s00417-005-0053-0. Epub 2005 Aug 2. Graefes Arch Clin Exp Ophthalmol. 2006. PMID: 16075223
-
Measuring accurate IOPs: Does correction factor help or hurt?Clin Ophthalmol. 2010 Jul 21;4:611-6. doi: 10.2147/opth.s11105. Clin Ophthalmol. 2010. PMID: 20668723 Free PMC article.
-
[Intraocular pressure and corneal thickness. A comparison between non-contact tonometry and applanation tonometry].Ophthalmologe. 2006 Jul;103(7):583-7. doi: 10.1007/s00347-006-1364-1. Ophthalmologe. 2006. PMID: 16786183 Clinical Trial. German.
-
[Transpalpebral tonometry with a digital tonometer in healthy eyes and after penetrating keratoplasty].Ophthalmologe. 2005 Jan;102(1):70-6. doi: 10.1007/s00347-004-1082-5. Ophthalmologe. 2005. PMID: 15322801 German.
References
-
- Marx W, Madjlessi F, Reinhard T, et al. [More than four years' experience with electronic intraocular needle tonometry] Mehr als vier Jahre Erfahrung mit der elektronischen intraokularen Nadel-Druckmessung bei irregularen Hornhauten. Ophthalmologe 1999;96:498–502. - PubMed
-
- Stodtmeister R, Kästner R, Pillunat LE. Saugnapfmethoden. In: Straub W, Kroll P, Küchle HJ, eds. Augenärztliche Untersuchungsmethoden. 1st ed. Stuttgart: Ferdinand Enke, 1995:436–61.
-
- Stodtmeister R, Hornberger M, Hofer M, et al. Okulo-Oszillo-Dynamographie nach Ulrich und Ulrich: Ergebnisse bei Augengesunden. Klin Monatsbl Augenheilkd 1988;192:219–33. - PubMed
-
- Ehlers N, Bramsen T, Sperling S. Applanation tonometry and central corneal thickness. Acta Ophthalmol (Copenh) 1975;53:34–43. - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources